5. Maintenance and conversion
Festo P.BE−CPA−EN en 0306d
Ô Ô Ô Ô Ô Ô
Ô Ô Ô Ô Ô Ô
Ô Ô Ô Ô Ô Ô
Ô Ô Ô Ô Ô Ô
Fig. 5/8: Fitting the electric sub−base
5. Place the end plate on the tie rods and screw the tie rod
screws several turns into the tie rods.
6. Align the CPA valve terminal on a flat surface so that the
components are not offset.
7. Tighten the screws of the tie rods in 2 stages as follows:
Stage
1
2
Tab. 5/2:
Tightening torques of the tie rods
CPA10
0.5 Nm
1.5 Nm
CPA14
0.5 Nm
2 Nm