1902
yes
Data backup – recover
1911
yes
Data backup – recover
1912
yes
Data backup – recover
1920
yes
Data backup – recover
2010
yes
DSA
2020
yes
DSA
2030
yes
DSA
2041
yes
DSA
2042
yes
DSA
2100
yes
DSA
2754
yes
Error self-test
2755
yes
Error self-test
2756
yes
Error self-test
2757
yes
Error self-test
2758
yes
Error self-test
2759
yes
Error self-test
2760
yes
Error IRT
**
2761
yes
Error IRT
**
2762
yes
Error IRT
**
*
Furnace head opens if this error occurs!
** A program in progress is aborted
*** Error cannot be acknowledged; programs cannot be started.
The new software includes program groups which were not yet available at
the time of the data backup. Only the existing program groups of the data
backup were restored.
The new software includes program parameters which were not yet
available at the time of the data backup. Please check the individual
program groups. The individual programs are no longer valid.
The new software includes program groups which were not yet available at
the time of the data backup. Please check the individual program groups.
The individual program groups are no longer valid.
The data backup could not be performed. Please install a newer software
version.
The tooth region was not determined.
The 3 shade guide teeth were not found.
The contour of the tooth was not determined.
The analysis region and the references differ significantly.
The analysis region is invalid. Select an analysis region on a tooth surface.
Unexpected error (# ****)
An error occurred while checking the infrared camera. Please switch the
furnace off and on again. If the error persists, please contact your Service
Center.
An error occurred while checking the infrared camera. Please switch the
furnace off and on again. If the error persists, please contact your Service
Center.
An error occurred while checking the infrared camera. Please switch the
furnace off and on again. If the error persists, please contact your Service
Center.
An error occurred while checking the infrared camera. Please switch the
furnace off and on again. If the error persists, please contact your Service
Center.
An error occurred while checking the infrared camera. Please switch the
furnace off and on again. If the error persists, please contact your Service
Center.
An error occurred while checking the infrared camera. Please switch the
furnace off and on again. If the error persists, please contact your Service
Center.
Check the orientation and positioning of the objects. The objects are
possibly too small or are placed in an unfavourable position on the firing
tray. Check if the protective foil has been removed from the sensor or if the
sensor has been contaminated. Check if a correct firing tray is used. The
height of the firing tray must correspond with the height of the firing trays
recommended for the respective materials by Ivoclar Vivadent AG.
Check the orientation and positioning of the objects. The objects are
possibly too small or are placed in an unfavourable position on the firing
tray. The object was not sufficiently dried in the specified time. Please
repeat the procedure after the object has cooled down.
An error occurred while trying to identify the object. Check if interfering
heat sources are in the visual range of the infrared camera. Sources of
interference are for example: other furnaces, air conditioning systems,
heaters, light bulbs, Bunsen burners, etc. Do not move the objects after the
start of a program.