5. Operation and Configuration
T3 – Temperature increase rate Stage 3
This parameter defines for the third temperature level by how many degrees per minute the furnace heats
up.
Value range °C: 10 – 140 °C/min; Value range °F: 18 – 252 °F/min
T3 – Holding temperature Stage 3
The holding temperature for the third temperature level defines the temperature at which a firing process
is conducted.
Value range °C: 100 – 1200 °C; Value range °F: 212 – 2192 °F
H3 – Holding time Stage 3
The holding time for the third temperature level indicates how long an object is fired at the holding
temperature.
Value range: 00:00 – 60:00 (mm:ss)
Vacuum on Stage 3
The parameter defines the temperature at which the vacuum for the third temperature level is activated.
Value range °C: Off or 1 – 1200 °C; Value range °F: 0 or 34 – 2192 °F
Vacuum off Stage 3
The parameter defines the temperature at which the vacuum for the third temperature level is deactivated.
If V2
corresponds to the holding temperature, the vacuum is maintained during the entire holding time.
3
Value range °C: Off or 1 – 1200 °C; Value range °F: 0 or 34 – 2192 °F
HL – Holding time long-term cooling
The holding time for the first cooling stage indicates how long an object is fired at the long-term cooling
temperature.
Value range: 00:00 – 60:00 (mm:ss)
Long-term cooling
If long-term cooling Stage 2 is activated, the furnace cools to the set temperature (L2) at the end of the
holding time with the furnace head closed.
Value range °C: Off or 50 – 1200 °C; Value range °F: 0 or 122 – 2192 °F
Cooling rate 2
This parameter defines by how many degrees per minute the temperature for the long-term cooling
Stage 2 has to be decreased.
Value range °C: 1 – 50 °C/min; Value range °F: 2 – 90 °F/min
H2L – Holding time long-term cooling
The holding time for the second cooling stage indicates how long an object is fired at the long-term
cooling temperature Stage 2.
Value range: 00:00 – 60:00 (mm:ss)
35