VDSL CO(POINT TO POINT)
II. Trouble shooting :
How to fix if VDSL CO & VDSL CPE cannot link, which caused by
speed change failure?
1. Re-connect both VDSL CO & VDSL CPE by short length phone wire
and without PBX(voice) signal
2. Re-power on VDSL CPE once
3. Change VDSL CO to its last speed mode
4. Wait for about 1 minute
5. Check if both LEDs of VDSL CO & VDSL CPE are on
6. Done
If you forgot the last speed mode of VDSL CO
Please try to change the from 4/1M to 15M until both link LEDs are on
<There are 4(four) speed modes – 4/1, 5, 10, 15Mbps>
Note :
Please wait for 1 minute after running the speed change program to
re-establish link.