V.35 cable are both power on. RC903-V35FE1 is integrated equipment. Move carefully and do not disassemble or mend it without the guidance of Dynamix technical engineer with the anti-static procedures. The equipment must be grounded. Do not disassemble the equipment by yourself.
2. Overview 2.1. Introduction RC 903-V35FE1 is an interface converter for V.35 equipment based on E1 network transmission. With growing utilization resources, many data transmission solutions using E1 link are accepted by users. RC 903- V35FE1 is standalone equipment, with built-in power supply, and can be placed on the table.
Page 5
Standalone , one E1 interface ( 75Ω unbalanced or 120Ω RC903-V35FE1-DC Balanced), one standard V35 DCE interface (ISO2593 M34 Female ) , -48VDC Module, one E1 interface(75Ω unbalanced), one standard V35 RC904-V35FE1 DCE interface, HDB26 male(transform to ISO2953 M34 female through attached cable) Module, one E1 interface (120Ω...
When connecting to DTE equipment such as Router through M34 interface, it is suggested to use special DTE cable for Router. When the DTE cable is not long enough, Dynamix can provide CBL-V35-M34F/M34M- D extension cable. When connecting to other DTE equipment through M34 interface, it is suggested to use cross-connect cable CBL-V35-M34M/M34M-X-D provided by Dynamix.
4. User Manual 4.1. Front panel Sketch of the front panel Power Indicator: Power (PWR): On: power is working in good condition Off: Power is off. V35 interface Indicator: TD Green: Flashing: when there is data flow of TD signal (sending data) at the V.35 interface.
Page 9
E1 interface alarm Indicator: LOS red: On: loss of receiving signal at local E1; Flashing: loss of receiving signal at remote E1 (only effective at fractional mode); Off: Local and remote signal are normal AIS red: On: Receiving all ‘1’ AIS alarm at the local E1 Flashing: Receiving all ‘1’...
4.2. Back panel Sketch of the back panel of AC equipment Sketch of the back panel of DC equipment Power interface: AC interface: standard 3 phase AC power supply interface. Please guarantee that it is correctly grounded. DC interface: DC ports: -48V, PGND, BGND, Please make sure that PGND is grounded;...
Page 13
Master clock (internal timing) V.35 Terminal clock ( followV.35 interface timing ) Slave clock (followE1 line timing) 2. 3 bit: selecting switch for auto follow function TS-FLOW (default OFF) Timeslot auto follow function Enable Disable To realize the setting of local timeslot bandwidth to follow the remote site, the following pre-conditions must be guaranteed: 1) This equipment is used point to point in pairs.
Page 14
which means that it has receive the correct test bit. If you choose to set the loop-back of the remote E1 line RLOOP, it means testing the whole process of signal. When testing the local E1 loop-back DLOOP, the bit error test function at the remote equipment and the local E1 loop-back function at the local equipment DLOOP should be on.
Page 15
and 8 bit: selecting switch of the loop-back type (default OFF) Local V35 Local E1 line Remote E1 line interface loop-back loop-back loop-back No loop-back No loop-back No loop-back The loop-back test function is the assistant function for the user to adjust equipment and test the link.
Page 16
2) There is no PCM equipment occupying Sa bit connecting in series in the E1 link 3) The local and remote equipment should not all be set to the transparent mode. As shown in the above figure, if the above conditioned is fulfilled, the related clock mode and bandwidth could be set.
4.4. Inside Jump pin definition When the user want to adjust the internal jump pin, please do it under the guidance or agreement of Dynamix technical engineer. Usually it is not necessary; unless it is in sever environment or disturbance.
4.5. Basic Connection The topological figures here are just for reference, users can design it according to practical application. The figures only take RC903-V35FE1 standalone converter as an example. Point-to-point fractional E1 mode in “Master clock — Slave clock” structure (Master clock) (Slave clock) As the above figure shows, when connecting Routers or other equipment with V.35...
Page 19
When using “Master Clock — Slave Clock” connection structure, if DXC and MUX devices are connected in series in E1 link, then DXC, MUX and remote converter should be at Slave Clock Mode (following E1 link clock). Point-to-point fractional E1 mode in “Terminal clock — Slave clock” structure (Terminal clock) (Slave clock)
Page 20
other manufactures. If Routers with E1 interface are used at remote side, users are required to first confirm all the parameters of E1 link, such as fractional/transparent E1, PCM30/31, CRC enable/disable, clock relations, bandwidth distribution and time slot usage etc. If any one of them does not match the setting of the converter, there will be problems in connection.
5. Equipment installation and Preparation 5.1. Installation preparation Make sure that the E1 line cable matches the equipment model connected to it. The default effective interface is 75Ω BNC. If user wants to use BALANCED interface, please set the 6 group of dip-switches on the bottom.
RLP indicator is on, local Router should indicate successful loop-back. If Dynamix converter does not work in pairs, then it is required to set parameters of E1 interface of other brand equipment consistent with settings of Dynamix local converter.
6. Troubleshooting If there are any problems during installation and operation, please try to solve them according to the following suggestions. If the problems still exist, please contact distributors for help. Power (PWR): indicator OFF Answer: Please check if there is any fault with power supply. Loss-of-Signal (LOS) alarm in E1 link: indicator ON Answer: LOS alarm caution that your E1 interface cannot receive signal.
Page 24
Compatibility with other V.35 Dynamix products Answer: RC903-V35FE1 and RC904-V35FE1 can cooperate with other Dynamix products that have similar functions, such as followings: 1. SUBM-FV35 V.35 module which can be installed in the standalone extendable Multiplexer. 2. RC800-30B-FV35, N x 64K V.35 interface PDH fiber-optic multiplexer, equipped with all the functions of RC903-V35FE1 and RC800-30B single E1 PDH fiber-optic multiplexer.
7. Appendix Explanation of CBL-V35-M34F/M34M-D cable This cable is used to extend v.35 cable. Converter Router CBL-V35-M34F/M34M-D Customer DTE Cable This cable is for the clients who have the need of extending cable. Please specify the length of cable when ordering. The making method is as follow: ISO2593Femal interface Standard V.35 Name...
Page 26
Converter. Converter Node CBL-V35-M34M/M34M-X-D Customer DTE Cable This cable is for the clients who have the need of cross end connection cable. Please specify the length of cable when ordering. The making method is as follow: The two ends of the cable is both M34 pin male interface Name of signal Pin number Pin number Name of signal...