MAIN MENU

When the system is in quiescent mode (ie, displaying the
date and time), entering a high level passcode affords the
user access to the main menu. The structure of this menu is
shown below.
MX Panel
Thu, 26-Jul-07
00:01
Company Name
General
Back
Each of the options available leads to further menus or
functions, which are described in the following paragraphs.
3.7

ACCEPT EVENTS

Allows displayed events to be accepted. Press 1 from the
main menu, the following type of screen will be displayed:
SYSTEM
Thu, 26-Jul-07
14:15
Company Name
General
Fault 02
Accept
Back
Use the F4 Key '<<' and F5 key '>>' keys to move between
events. Usr F3 'Accept' to accept an event.
3.8

VIEW STATUS

Allows the status of all points and zones on the system to be
viewed. Press 2 from the Main menu, the following type of
screen will be displayed:
© 2009 Tyco Safety Products
Registered Company: Thorn Security Ltd. Registered Office: Dunhams Lane Letchworth Garden City Hertfordshire SG6 1BE
Main menu
1 - Accept Events
2 - View Status
3 - Isolate/De-Isol
4 - Time / Date
5 - Event Log
6 - View/Print Data
7 - Service
8 - Configuration
9 - Test Buzzer,
LEDs & Display
Alarm Count:
0021
Accept Events
Zone 000
R10
System Zone
Battery Fault IP
BATTERY FAULT
01-Mar-00 14:15:02
Digital Input
1000
>>
<<
EQUIPMENT:
PUBLICATION:
ISSUE No. & DATE:
MX Panel
Wed, 01-Mar-08
14:15
Company Name
General
Back
Point Complete - allows the status of all points on the
system (both inputs and outputs) to be checked.
Point Input - allows the status of only input devices to be
checked (eg, detectors).
Point Output - allows the status of only output devices to
be checked (eg, functional bases, sounder etc.).
Zone - allows the total status of all points in a specified zone
to be checked.
Zone Maps - a zone map can be displayed for Alarm, Fault,
Test and Isolated Inputs states. A grid of 80 zones is
displayed which can be scrolled between pages.
Network Status - allows the status of panels on the network
to be checked (only if a network is configured).
Select the required number from the View Status menu, the
following type of screen will be displayed:
MX Panel
Thu, 26-Jul-07
14:15
Company Name
General
Back
Select the type of Point or Zone:
1) Loop Point (Addressable Loop).
2) RBus Point.
3) Local I/O Point.
MX/MZX
17A-04-S
17
10/09
View Status
1 - Point
2 - Point I/P only
3 - Point O/P only
4 - Zone
5 - Zone Maps
6 - Network Status
View Status
Point
1 - Loop Point
2 - RBus Point
3 - Local I/O Point
PAGE 11 of 40