Power-Up And Initialization Led Codes; Power-Up And Initialization Led Codes (1111 Xxxx - Digital Equipment VAXstation 4000/60 Condensed Service Information

Table of Contents

Advertisement

B.3 Power-Up and Initialization LED Codes
Table B–1 lists the system power-up and initialization LED codes.
Table B–1 Power-Up and Initialization LED Codes (1111 XXXX)
LED
3
LED Depiction
Code
1111 1111
FFh
1111 1110
FEh
1111 1101
FDh
1111 1100
FCh
1111 1011
FBh
1111 1010
FAh
1111 1001
F9h
1111 1000
F8h
1111 0111
F7h
1111 0110
F6h
1111 0101
F5h
1111 0100
F4h
1111 0011
F3h
3
In this column, 1 indicates the LED is on; 0 indicates the LED is off.
Description
Power has been applied but no
instruction has been run
ROM has been entered and initializa-
tion and testing have started
Waiting for memory to initialize
Sizing memory in the system
Running a byte mask test on the
memory needed by the console
A full memory data path test is being
performed on the memory needed by
the console
Initializing the console data structures
Performing auto configuration on the
machine
Testing the NVR device
Testing the DZ device
Testing the graphics output device
Initializing the console device
Entering the console program
FRU
System module
System module
System module, memory
modules
System module, memory
modules
System module, memory
modules
System module, memory
modules
System module
System module
System module
System module, mouse,
keyboard
System module, graphics
module
System module, graphics
module
System module
Reading the Diagnostic LED Codes B–3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vaxstation 4000 vlc

Table of Contents