A.2 Error Codes: Self-Tests, Systems Tests, and Utilities
The following tables describe the self-tests, system tests, and utilities for the
Model 60 and VLC systems.
The following tables apply to both the Model 60 and VLC systems,
unless specified otherwise.
In the self-test tables, decimal errors display after the self-test, and
hexadecimal errors display after the extended test.
A.2.1 TOY/NVR Self-Test Error Codes
The TOY/NVR self-test produces the error codes in the following table:
Table A–2 TOY/NVR Test Error Codes
Error
Decimal
4
8
12
16
32
36
44
48
64
65
72
96
Notes
Hexadecimal
Meaning
4
Battery was found to be bad
8
NVR register test has failed
C
Battery down and NVR register test has failed
10
TOY register test has failed
20
Valid RAM and time bit have failed to set
24
VRT bit failure and battery was found to be bad
2C
Battery down, VRT failure, and NVR test has
failed
30
TOY register test and VRT have failed
40
Battery check test has failed; hard error
41
Battery check test has failed; soft error
48
Battery check test and NVR register test have
failed
60
VRT bit failure and battery check test has failed
(continued on next page)