12. Communication

12.4 Dial Address

The dial address for each of the units on network consists of 4 digits. This is split into
2 parts of 2 digits.
For standalone application Panel Number = Panel ID (Default value: 01), Outstation
number ranges from 01 – 16.
Example: To Call Outstation #5 connected to Panel #1, dial – 0105.
68
InStALLAtIon And opErAtIon mAnuAL 25-13741-E January 2020 www.eaton.com
00 00
Panel Number
Figure 41. dialing number
1
1
2 2
3
3
Accept
Down
Up
Back
Outstation Number
4
4
5
5
6
6
7
7
8
8
9 9
10
10
Speak Only
Listen In
Hold Call
Cancel Call
Accept Call
11
11
12
12
13
13
14
14
15
15
16
16