DentalEZ aXcs Series Installation, Operation And Care Manual

Wall/cabinet mounted unit

Advertisement

aXcs
Wall/Cabinet Mounted Unit
®
Installation, Operation and Care Manual
DentalEZ Alabama, Inc.
2500 Highway 31 South
Bay Minette, AL 36507

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the aXcs Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DentalEZ aXcs Series

  • Page 1 Wall/Cabinet Mounted Unit ® Installation, Operation and Care Manual DentalEZ Alabama, Inc. 2500 Highway 31 South Bay Minette, AL 36507...
  • Page 2: Table Of Contents

    Table of Contents Section I Introduction Section V Operation Introduction ............. 2 Delivery System............. 18 Basic Components ........... 2 Handpiece ............18-19 Specifications ............3 Foot Control ............19 DWM/DCM Dimensions ........ 3 Syringe ..............19 DWM/DCM Extended Dimensions ..... 3 Chipblower (Optional) ........
  • Page 3: Introduction

    This manual contains installation, operation and care To ensure correct installation, carefully read all the instructions and user service information for the procedure instructions contained in this manual DentalEZ aXcs Wall/Cabinet Unit. paying close attention to all notes, cautions and ®...
  • Page 4: Specifications

    Section I Introduction Specifications DWM/DCM DIMENSIONS 22" Power Supply 18-1/4" • 115 VAC, 50/60 Hz., as applicable 1-3/4" • 220 VAC, 50/60 Hz., as applicable - 80 PSI Air Pressure 14-1/4" - 40 PSI Water Pressure 19-1/4" 20-1/4" Clean Water System (Optional) Reservoir Capacity - .75 to 1 liter 9-1/2"...
  • Page 5: Standard Features

    For any questions about an order, please All parts supplied are necessary for proper installa- contact a DentalEZ Equipment customer tion, so be sure not to discard any hardware or com- service representative at 1-866-DTE-INFO.
  • Page 6: Section Ii Pre-Installation

    Section II Pre-installation USC Carton Contents: Wall Mounted Unit • • USC cover To ensure the most successful operation of the wall • USC base (floor plate) mounted unit and provide the dentist with maximum • Bag of supplies: flexibility and convenience, do the following: Two #6 x 3/8"...
  • Page 7 ® aXcs Wall/Cabinet Unit Section II Pre-installation 2. Using the full-size USC template found in the — NOTICE — back of this manual, orient the air stop valve Set the USC cover aside until all and water stop valve (as shown in the picture installation and testing is complete.
  • Page 8: Cabinet Mounted Unit

    Section II Pre-installation Electrical Contractor's Procedure Cabinet Mounted Unit — NOTICE — To ensure the most successful operation of the cabinet Electrical contractor's parts are not supplied. mounted unit and provide the dentist with maximum flexibility and convenience, consider the unit's dimen- sions and use the DCM rotation/reach diagram below The electrical contractor is to provide a covered 115 as a guide to select the best mounting location that will...
  • Page 9: Section Iii Installation

    ® Section III Installation aXcs Wall/Cabinet Unit NOTE: Once the location of the unit has been DRY WALL — Attach the bracket to the wall established, carefully perform the following wall mount or optional mounting panel using four 1/4-20 or cabinet mount installation procedures: cap screws, lock washers and T-nuts.
  • Page 10 Section III Installation Unit Head Assembly Air & Water Tubings 1. Place the nylon bushing inside the pivot 1. Position the end of the umbilical under the cylinder of the mounting bracket. pivot cylinder. 2. Slowly insert the fixed arm pivot (with wiring 2.
  • Page 11 ® Section III Installation aXcs Wall/Cabinet Unit 4. Then secure the yellow signal air line using a Covers and Umbilical 1/8" tubing clamp. 1. Insert the umbilical approximately one inch 5. Connect the red air line from umbilical to the up into the bottom of the pivot cylinder.
  • Page 12: Cabinet Mounted Unit

    Section III Installation Cabinet Mounted Unit Leveling Plate Installation Tools Required: • Torpedo level T -nuts • Drill • Set of Allen wrenches 1/4-20 Cap Screws (4) 5/64" hex tool and Lock Mounting 1/8" hex tool Washers (4) Bracket • Small-slotted screwdriver Mounting Bracket 4.
  • Page 13 ® Section III Installation aXcs Wall/Cabinet Unit Unit Head Assembly Utilities Connection 1. Place the nylon bushing inside the pivot 1. Connect the 14" red tubing from the air cylinder of the mounting bracket. regulator to the air shut off. 2.
  • Page 14: Fiber Optics-Electrical (Optional)

    Section III Installation Foot Control Tubings & Covers Fiber Optics-Electrical (Optional) 1. Position the foot control tubing with cover NOTE: For fiber optics electrical connections, see the attached on the preferred side of the mounting wiring diagram in the back of this manual. bracket.
  • Page 15: Handpiece Tubing

    ® aXcs Wall/Cabinet Unit Section III Installation 7. In the DWM/DCM, plug the connector of Electrical Lead the black and white wire leads from the arm Alignment Pin into the fiber optics power pack transformer. 8. Plug the power pack transformer into the standard electrical receptacle.
  • Page 16: Chipblower (Optional)

    Section III Installation 4. Connect the syringe to the valve body and 5. Install the chip air valve assembly on the foot install the nozzle tube assembly following the control base and secure it using the three flat- instructions in the owner’s manual supplied head screws included in the kit.
  • Page 17: Section Iv Testing

    ® Section IV Testing aXcs Wall/Cabinet Unit 1. Pull the locking knob. Delivery System 2. Turn the adjustment knob on each regulator NOTE: until the correct pressure reading is reached. Before testing the deliver y system, make sure the shipping tie wrap is removed from the adjustable 3.
  • Page 18: Syringe

    Section IV Testing e. Allow water to flow freely from all tubings e. Using a slotted screwdriver, turn the air for approximately two minutes to ensure pressure adjustment screw on the control all air has escaped. valve of the appropriate handpiece (counterclockwise to increase pressure, clockwise 3.
  • Page 19: Section V Operation

    ® Section V Operation aXcs Wall/Cabinet Unit • An oil collector/ Delivery System filter is designed to collect oil from the Master Switch Controls handpiece exhaust Oil Collector/ air. Periodically Filter The master toggle switch, check the filter for cleaning or replacement by located in the rear of the lifting the delivery head cover and removing the delivery unit, controls the...
  • Page 20: Foot Control

    Section V Operation 2. While operating the handpiece, turn the valve Foot Control counterclockwise to increase the volume of coolant water spray. To decrease the volume, The speed of the handpiece is controlled by depress- turn the valve clockwise. ing the disk located on the foot control. •...
  • Page 21: Section Vi Care

    Do not use disinfectants that contain any of the following: — NOTICE — Cleaning brushes and Vac-U-Ez solution can Iodophors Glutaraldehydes • • be ordered through DentalEZ dealers. Phenols Sodium Hypochlorites • • NOTE: *Cavicide is the recommended disinfectant ™...
  • Page 22: Section Vii User Service Information

    Section VII User Service Information A full-color tubing diagram of the aXcs delivery — WARNING — system is located at the end of this manual. Exercise extreme caution when troubleshooting The following charts should be used when trouble- the electrical components of the aXcs DWM/ shooting operational problems.
  • Page 23: Arm System

    ® Section VII User Service Information aXcs Wall/Cabinet Unit Arm System Delivery Head (continued) l a t t i n y l r y f i i t i . l e y f i y l r t f i .
  • Page 24 Section VII User Service Information Handpiece (continued) y t l e l i t a l o l f t a l o l f y t l t , l y t l t i n , y l y r t .
  • Page 25: Service Instruction

    Service Instruction Model No. If the problem is not addressed or cannot be isolated by performing the suggested troubleshooting proce- Serial No. dures, contact your local DentalEZ full-service dealership. Be prepared to supply the following product information: • Model Name •...
  • Page 26: Section Viii Parts List/Diagrams

    Section VIII Parts List/Diagrams Utility Service Center t l i t a l t l i t a l t a l t a l & t a l t a l t l i t a l ® aXcs Wall/Cabinet Unit...
  • Page 27: Delivery Head

    ® Section VIII Parts List/Diagrams aXcs Wall/Cabinet Unit Delivery Head c i t Air/Water Syringe e l l & t l i r t r Installation, Operation and Care Manual...
  • Page 28: Arm Assembly

    Section VIII Parts List/Diagrams Arm Assembly i l y Foot Control ® aXcs Wall/Cabinet Unit...
  • Page 29: Product Support Services

    DentalEZ Equipment Division aXcs Wall/Cabinet Unit DentalEZ and its employees are proud of the products we provide in the dental community. We stand behind these products with a warranty against defects in material and workmanship as provided below. And, we have our own in-house repair facility to service our products.
  • Page 30 aXcs Wall/Cabinet Mount Template ® 4 x Ø 5/16" 2" through MOUNTING BRACKET 1. Mark the top right hole f or the T-nuts 1-1/2" 13" abo ve the floor . Also, for cabinet mounted units , mark the hole Ø 1-1/4" through 2"...
  • Page 31 Chair Side 18-3/4" USC Base Suggested Electrical Outlet Location 15-1/8" ± 1/32" 4-3/4" 5-11/16" 3-11/16" Ø 7/8" through 5-1/8" 1-1/8" 2-1/8" DRAIN 13" Horizontal Center Line WATER 8-5/8" ± 1/32" VACUUM 2" 1/2" 3 x Ø 5/8" through 7-9/16" Chair Center Line 4 x For #10-32 Anchors USC Base...
  • Page 32: Tubing Diagram

    Wall/Cabinet Unit aXcs ® DELIVERY HEAD Tubing Diagram 1/16" Twin Sterling Syringe Wire Assembly, Fiber Optics (Black & White) Wire Assembly, Scaler or Curing Light 1/4" Red (Blue & Gray) Master Collector 1/8" Red 1/8" 1/8" Red Blue 1/8" Yellow (Signal Air) 1/8"...
  • Page 33 2500 HIGHWAY 31 SOUTH BAY MINETTE, ALABAMA 36507 PHONE: 1-866-DTE-INFO FAX: (251) 937-0461 P. N. 2717-199B © Den-tal-ez, Inc. Printed in U. S. A. February, 2002...