4.3.5 Panel Board

1.
Remove the Upper Housing.
(4.3.3 Upper Housing on page 35)
2.
Remove the screw (C.B.P. 3x8, 5-7 kgf.cm) that secure the Panel Board.
3.
Disconnect CN1 connector from the Panel Board, and remove the Panel Board.
CN1
Figure 4-8. Removing the Panel Board
When reassembling the Panel Board, match the notch to the rib of
the Lower Housing.
(Figure 4-8 on page 37 )
REASSEMBLY
DISASSEMBLY/ASSEMBLY
C.B.P. 3x8
Panel Board
Notch and Rib

4.3.6 Main Board

1.
Remove the Panel Board.
2.
Remove the two screws (C.B.P. 3x8, 5-7 kgf.cm/C.B.S 3x5, 6-8 kgf.cm) that
secure the Grounding Plate, and remove it.
C.B.S. 3x5
The screw described in the next step secures the Upper Main Board
C H E C K
P O I N T
Shield Plate together with the earth cable for the Perfection V100
Photo/V200 Photo/V350 Photo.
3.
Remove the screw (C.B.P. 3x8, 5-7 kgf.cm) that secures the Upper Main Board
Shield Plate.
4.
Remove the Upper Main Board Shield Plate from the gap between the Lower
Housing and the Lower Main Board Shield Plate.
Upper Main Board Shield Plate
Lower Housing
Figure 4-10. Removing the Upper Main Board Shield Plate
Disassembly of Main Unit
(4.3.5 Panel Board on page 37)
Grounding Plate
Figure 4-9. Removing the Grounding Plate
(Figure 4-11 on page 38 )
Lower Main Board Shield Plate