Description
See Figure 1. The Drum Level Detect Module uses roller
plunger limit switches on guide rails to monitor the
distance between the bottom of the follower/platen and
the base surface of the bulk unloader frame.
The actuating rod connects to the bulk unloader
crossover bar. It actuates each roller plunger on the limit
switches during the downward movement of the
follower/platen.
FOLLOWER/PLATEN
Figure 1
Drum Level Detect Assembly
E 2008 Nordson Corporation
r
Rhino
SD2CE/XD2H Drum Level Detect Module
Issued 2/08
The assembly detects three conditions during the
downward movement of the follower/platen:
S
Follower/Platen in drum
S
Drum Low
S
Drum Empty
Refer to the Adjusting Limit Switches section for more
information on setting the limit switches.
CROSSOVER BAR
ROLLER PLUNGER
LIMIT SWITCH
ACTUATING ROD
GUIDE RAILS
Instruction Sheet: 1085716A

Advertisement

loading

Summary of Contents for Nordson Rhino SD2CE

  • Page 1 CROSSOVER BAR ACTUATING ROD GUIDE RAILS FOLLOWER/PLATEN ROLLER PLUNGER LIMIT SWITCH Figure 1 Drum Level Detect Assembly E 2008 Nordson Corporation Issued 2/08 Instruction Sheet: 1085716A...
  • Page 2 Rhino SD2CE/XD2H Drum Level Detect Module Repair Wiper Seal 1. See Figure 2. Remove the screws (6) and Repairs consist of replacing the actuating rod wiper seal washers (5) securing the cover (4) to the base along with replacing and adjusting the roller plunger plate (9).
  • Page 3: Limit Switch

    Rhino SD2CE/XD2 Drum Level Detect Module Limit Switch 1. See Figure 2. Remove the screws (6) and 5. Slide the limit switch (5) toward the actuating rod (7) washers (5) securing the cover (4) to the base until the limit switch roller plunger is compressed plate (9).
  • Page 4: Adjusting Limit Switches

    Rhino SD2CE/XD2H Drum Level Detect Module Adjusting Limit Switches See Figure 4 and review the following switch descriptions 3. Slide the switch bracket (3) to the desired height and in Table 1 before making adjustments. Perform the tighten the set screws (1).
  • Page 5 Rhino SD2CE/XD2 Drum Level Detect Module Parts See Figures 5 or 6 and refer to the following parts list. To order parts, call the Nordson Customer Service Center or your local Nordson representative. Figure 5 Parts Item Part Description —...
  • Page 6 Rhino SD2CE/XD2H Drum Level Detect Module WIPER ORIENTATION Figure 6 Parts (Continued) Item Part Description — 1081662 Level detect module, drum, Rhino XD2H S Rod 1081667 S Screw, socket, M6 x 12 982910 S Plate, mounting 1081671 S Wiper, heel, 0.500 x 0.750 x 0.210...

This manual is also suitable for:

Rhino xd2h