Appendix A
Specifications
Power disconnect ....................................The AC power cable provides
DC Output
DC current capacity (I
Note
Maximum total usable power is 353.6 W.
Backplane slot current capacity
Slot
System Controller Slot
System Timing Slot
Hybrid Peripheral Slot with
PXI-1 Peripheral
Hybrid Peripheral Slot with
PXI-5 Peripheral
PXI-1 Peripheral Slot
NI PXIe-1062Q User Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
)
MP
Voltage
+3.3 V
+5 V
+12 V
–12 V
5 V
AUX
+5 V
V (I/O)
15 A
6 A
5 A
6 A
11 A
A-2
main power disconnect. The
front-panel power switch causes
the internal chassis power supply
to provide DC power to the
CompactPCI/PXI Express
backplane. You also can use the
rear-panel D-SUB 9-pin
connector and power mode switch
to control the internal chassis
power supply.
Maximum Current
32 A
30 A
25 A
1.5 A
2 A
+3.3 V
+12 V
–12 V
15 A
30 A
6 A
4 A
6 A
1 A
1 A
6 A
4 A
6 A
1 A
1 A
5 V
AUX
1 A
1 A
1 A