CALIBRATION PROCEDURE
PXIe-1095
PXI Chassis
This document contains the verification and adjustment procedures for the National
Instruments PXIe-1095 chassis. Refer to
calibration solutions.
Contents
Software.................................................................................................................................... 1
Documentation..........................................................................................................................1
Test Equipment......................................................................................................................... 2
Test Conditions......................................................................................................................... 2
Initial Setup...............................................................................................................................2
Verification................................................................................................................................3
Adjustment................................................................................................................................4
Reverification............................................................................................................................5
Where to Go for Support.......................................................................................................... 5

Software

Calibrating the PXIe-1095 requires the installation of the following software on the calibration
system:
PXI Platform Services 18.1 or later
You can download PXI Platform Services from ni.com/downloads.
PXI Platform Services supports programming the calibration procedures using a number of
application development environments (ADEs), including LabVIEW, LabWindows
and Microsoft Visual C++. When you install PXI Platform Services, you need to install
support only for the ADE that you intend to use.

Documentation

You might find the following documents helpful as you perform the calibration procedure:
PXIe-1095 User Manual
PXIe-1095 Specifications
The latest versions of these documents are available on http://www.ni.com/manuals.
ni.com/calibration
for more information about
/CVI
,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXIe-1095 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments PXIe-1095

  • Page 1 Verification..........................3 Adjustment..........................4 Reverification..........................5 Where to Go for Support......................5 Software Calibrating the PXIe-1095 requires the installation of the following software on the calibration system: • PXI Platform Services 18.1 or later You can download PXI Platform Services from ni.com/downloads. PXI Platform Services supports programming the calibration procedures using a number of ™...
  • Page 2: Initial Setup

    Table 1. on page Initial Setup Refer to the PXIe-1095 User Manual for information about how to install the software and hardware and how to configure the device in Measurement & Automation Explorer (MAX). 2 | ni.com | PXIe-1095 Calibration Procedure...
  • Page 3 Complete the following procedure to determine the as-found status of the PXIe-1095 chassis. Verifying OCXO Frequency Accuracy Connect the 10 MHz Ref Out SMA on the rear of the PXIe-1095 chassis to Channel 1 of the Frequency Counter. Configure the Frequency Reference to output a 10 MHz sine wave on one of its output channels.
  • Page 4 Complete the following procedure to adjust the OCXO frequency accuracy of the PXIe-1095 chassis: Get a resource handle for the PXIe-1095 to calibrate using the System Configuration API. Call Initialize Session to set up a new session. Call Create Filter to create a new filter for searching for devices. Set the IsChassis...
  • Page 5 NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support...
  • Page 6 For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the file on your media, or the National Instruments Patent Notice patents.txt . You can find information about end-user license agreements (EULAs) and third-party legal notices ni.com/patents...