Multisystem extension interface for pci express, compactpci express, and pxi express bus systems (38 pages)
Summary of Contents for National Instruments PXI Express Series
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
PXI Express NI PXIe-8101/8102 User Manual NI PXIe-8101/8102 User Manual June 2010 372866B-01 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 4
Instruments Corporation. National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
Page 5
Operation of this hardware in a residential area is likely to cause harmful interference. Users are required to correct the interference at their own expense or cease operation of the hardware. Changes or modifications not expressly approved by National Instruments could void the user’s right to operate the hardware under the local regulatory rules.
Benefits of PXI Express....................1-1 NI PXIe-8101/8102......................1-2 Description ......................1-2 Functional Overview ..................1-2 NI PXIe-8101/8102 Functional Description ........1-2 National Instruments Software ..................1-4 Chapter 2 Installation and Configuration Installing the NI PXIe-8101/8102..................2-1 How to Remove the Controller from the PXI Express Chassis.......2-4 BIOS Setup ........................2-4 Accessing BIOS Setup Utility .................2-5...
About This Manual This manual contains detailed instructions for installing and configuring the National Instruments PXIe-8101/8102 embedded computer kit. How to Use the Documentation Set Begin by reading the NI PXIe-8101/8102 Installation Guide, a brief quick-start guide that describes how to install and get started with your controller.
About This Manual Text in this font denotes text or characters that you should enter from the monospace keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions.
Chapter 1 Introduction The demanding timing and synchronization requirements of instrumentation systems are met by the integrated features of PXI Express. Not only are the trigger bus, 10 MHz system reference clock, and star trigger bus available in PXI retained by PXI Express, but new timing and synchronization features that include a 100 MHz differential system reference clock for the synchronization of multiple modules and three differential star trigger buses for the distribution of precise clock and trigger...
• The SATA block connects a Serial ATA hard drive to the ICH9M. National Instruments Software National Instruments has developed several software tools you can use with the NI PXIe-8101/8102. National Instruments’ hardware and software work together to help you make the most of your PXI Express system.
Page 15
RTSI or PXI synchronization, self-calibration, messaging, and acquiring data to extended memory. For more information visit ni.com/daq National Instruments’ Modular Instruments use specialized drivers suited to each product’s specialization. Express VIs provide customized, interactive programming of instruments in a single interface and soft front panels provide an interface for testing the functionality of each instrument with no programming required.
Page 16
Chapter 1 Introduction NI-VISA is the National Instruments implementation of the VISA specification. VISA is a uniform API for communicating and controlling USB, Serial, PXI, VXI, and various other types of instruments. This API aids in the creation of portable applications and instrument drivers. For...
Page 18
Chapter 2 Installation and Configuration Remove the protective plastic covers from the four bracket-retaining screws as shown in Figure 2-1. 1 Protective Screw Cap (4X) Figure 2-1. Removing Protective Screw Caps Make sure the injector/ejector handle is in its downward position. Align the NI PXIe-8101/8102 with the card guides on the top and bottom of the system controller slot.
Page 19
Chapter 5, Troubleshooting. Figure 2-2 shows an NI PXIe-8101 installed in the system controller slot of a National Instruments NI PXIe-1062 chassis. An NI PXIe-8102 would appear the same installed in the chassis. 1 NI PXIe-1062 Chassis 3 Injector/Ejector Rail 2 NI PXIe-8101 Controller Figure 2-2.
Chapter 2 Installation and Configuration How to Remove the Controller from the PXI Express Chassis The NI PXIe-8101/8102 controller is designed for easy handling. To remove the unit from the PXI Express chassis, complete the following steps. Power off the chassis. Remove any cables that may be attached to the controller front panel.
Chapter 2 Installation and Configuration • System Memory—This value indicates the size of system RAM detected by the BIOS. • Chassis Link Configuration—This value displays the PXI Express link configuration, either 2-Link or 4-Link. If 2-Link is displayed, the NI PXIe-8101/8102 detected a 2-link PXI Express backplane and is operating with two x1 PCI Express links.
Chapter 2 Installation and Configuration • Processor Type, Speed, and Number of Cores—These values indicate the type of processor used in the NI PXIe-8101/8102 controller, the speed of the processor, and the number of processor cores. Video Configuration Submenu Use this submenu to apply alternate settings to the video configuration. Normally, you do not need to modify these settings, as the factory default settings provide the most compatible and optimal configuration possible.
Chapter 2 Installation and Configuration Note Certain real-time applications may require you to disable this setting to reduce loop time jitter. When the controller is configured to boot LabVIEW RT, legacy USB support is automatically disabled. • Device Reset Delay—This setting specifies the number of seconds the Power-On Self Test will wait for a USB mass storage device to start.
Chapter 2 Installation and Configuration Note By default, the target will automatically attempt to connect to the network using DHCP. If the target is unable to initiate a DHCP connection, the target connects to the network with a link-local IP address or 169.254.x.x •...
Chapter 2 Installation and Configuration CD/DVD ROM Drive BBS Priorities Submenu • Boot Option #1, Boot Option #2, Boot Option #3—These settings specify the boot priority of CD/DVD ROM drive devices. The highest priority device is displayed on the main Boot Option Priorities list. Optionally, each device can also be Disabled if the device should never be used as a boot device.
Chapter 2 Installation and Configuration System CMOS The NI PXIe-8101/8102 contains a backed-up memory used to store BIOS configuration information. Complete the following steps to clear the CMOS contents: Power off the chassis. Remove the controller from the chassis. Press and hold down push-button switch SW2 for 2 to 3 seconds. The switch location is shown in Figure 2-3.
Chapter 2 Installation and Configuration LabVIEW RT Installation This section explains software installation and switch configuration for LabVIEW RT on your PXI controller. LabVIEW RT Software Installation The following section describes the necessary steps to get your PXI embedded controller setup to run LabVIEW Real-Time. In this section you will configure the boot mode of the controller, verify or change IP settings, and install LabVIEW Real-Time software.
Page 36
Chapter 2 Installation and Configuration Figure 2-4 shows the RT Series PXI target, PXIe-8101, configured to automatically obtain an IP address from a DHCP server, as indicated in the IP Settings section of the figure. The NI PXIe-8102 would appear similar in MAX.
Chapter 2 Installation and Configuration Figure 2-5 shows the location of the LabVIEW RT configuration switches. The switches are shown in the OFF position. 1 Switch 1—Boot LabVIEW RT 3 Switch 3—Disable Startup VI 2 Switch 2—Boot Safe Mode 4 Switch 4—Reset IP Address Figure 2-5.
PXI Chassis Configuration The PXI Platform Services software installed on your controller and available on the National Instruments Driver CD included with your kit automatically identifies your PXI Express system components to generate file. You can configure your entire PXI pxiesys.ini...
Chapter 2 Installation and Configuration Figure 2-6. Multichassis Configuration in MAX PXI System Configuration Launch Measurement & Automation Explorer (MAX). In the Configuration tree, expand Devices and Interfaces. In the Devices and Interfaces tree, expand PXI System. Your PXI Express chassis is already identified and appears in the PXI System tree.
PC2-6400 4 GB, 512 MB × 64, 1.18 in. max • Note National Instruments has tested and verified that the DDR2 SO-DIMMs we sell work with the NI PXIe-8101/8102. We recommend you purchase your DDR2 SO-DIMM modules from National Instruments. Other off-the-shelf DDR2 SO-DIMM modules are not guaranteed to work properly.
Chapter 2 Installation and Configuration 1 DDR2 SO-DIMM Socket 2 DDR2 SO-DIMM Module Figure 2-7. Installing a DDR2 SO-DIMM in an NI PXIe-8101/8102 Controller Hard Drive Recovery NI PXIe-8101/8102 controllers include two methods of restoring the original factory condition of your hard drive. Hard drive-based recovery stores a factory backup on a separate portion of your hard drive allowing you to restore your controller without additional media.
Chapter 3 I/O Information Front Panel Figure 3-1 shows the front panel layout and dimensions of the NI PXIe-8101. The NI PXIe-8102 has the same front panel layout and dimensions. Dimensions are in inches (millimeters). 4.393 in. (111.58 mm) 3.747 in. (95.17 mm) 3.551 in.
Chapter 3 I/O Information Ethernet Figure 3-4 shows the location and pinouts for the Ethernet connector on the NI PXIe-8101/8102. Table 3-4 lists and describes the Ethernet connector signals. Ethernet Figure 3-4. Ethernet Connector Location and Pinout Table 3-4. Ethernet Connector Signals Fast Ethernet Gigabit Ethernet TX_A+...
Figure 3-5 shows the location and pinouts for the IEEE 1284 (parallel) connector on the NI PXIe-8101/8102. Table 3-6 lists and describes the IEEE 1284 connector signals. Parallel port adapter cables are available from National Instruments, part number 777169-01. Parallel Port Figure 3-5.
Page 51
Chapter 3 I/O Information Table 3-6. Parallel Port Connector Signals Default Configuration (LPT) Signal Name Signal Description BUSY Device Busy SLCT Select ACK# Acknowledge FAULT#(ERROR#) Fault PAPEREND Paper End Data Bit 0 Data Bit 1 PD 2 Data Bit 2 Data Bit 3 Data Bit 4 Data Bit 5...
Chapter 3 I/O Information Figure 3-7. Installing a Ferrite on a Single USB Cable Trigger The TRIG connector is the software-controlled trigger connection for routing PXI triggers to or from the backplane trigger bus. Figure 3-8 shows the TRIG connector location on the NI PXIe-8101/8102. Table 3-8 lists and describes the trigger connector signals.
Chapter 4 Common Configuration Questions Boot Options What devices can I boot from? The NI PXIe-8101/8102 can boot from the following devices: • The internal Serial ATA hard drive • An external SCSI hard drive or CD/DVD-ROM if an SCSI adapter, such as the PXI-8214, is used •...
The NI PXIe-8101/8102 has no PS/2 connector, and you need to use a USB Y-splitter cable as shown in Figure 4-1, or a similar device, to connect both a PS/2 mouse and PS/2 keyboard. National Instruments Part Number 778713-01 is such a cable and is available through the online catalog at ni.com/products...
If you share the USB CD/DVD-ROM drive on the other computer, you can map the shared USB CD/DVD-ROM drive to a drive letter on the NI PXIe-8101/8102. A USB CD/DVD-ROM drive is available from National Instruments, part number 778492-01. NI PXIe-8101/8102 User Manual ni.com...
PC2-6400 4 GB, 512 MB × 64, 1.18 in. max • Note National Instruments has conducted thermal testing as well as mechanical shock and vibration testing, and has verified that the DDR2 SO-DIMMs we sell work with the NI PXIe-8101/8102. We recommend you purchase your DDR2 SO-DIMM modules from National Instruments.
Windows 2000 or Windows XP. Refer to the Boot Options section for more information. A USB floppy drive is available from National Instruments, part number 778492-02. PXI Express Configuration How do I use the SMB trigger on the front panel?
Page 61
Does your monitor work with a different PC? If it hangs, note the last screen output that you saw for reference when consulting National Instruments technical support. • What has changed about the system? Did you recently move the...
Page 62
Chapter 5 Troubleshooting • Recover the hard drive on the controller. (Refer to the Hard Drive Recovery section of Chapter 2, Installation and Configuration.) • Make sure the RAM is properly seated. My controller boots fine until I get to Windows, at which point I cannot read the screen.
Page 65
Appendix A Specifications Electrical NI PXIe-8101 Current (Amps) Voltage (V) Typical Maximum +3.3 V 2.25 A 4.75 A +5 V 1.25 A 2.25 A +12 V 1.5 A 2.25 A –12 V +5 V Aux .330 A .400 A Note: Does not include any attached USB devices. NI PXIe-8102 Current (Amps) Voltage (V)
Page 67
Appendix A Specifications Shock and Vibration Operating Shock ........30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) Random Vibration Operating .........5 to 500 Hz, 0.3 g (with solid-state hard drive) Nonoperating ........5 to 500 Hz, 2.4 g (Tested in accordance with IEC-60068-2-64.
Page 69
Return Material Authorization (RMA) process or contact an authorized National Instruments service representative. For more information about compliance with the EU Battery Directive 2006/66/EC about Batteries and Accumulators and Waste Batteries and Accumulators, visit ni.com/environment/batterydirective National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china...
Page 70
Technical Support and Professional Services Visit the following sections of the award-winning National Instruments Web site at for technical support and professional services: ni.com • Support—Technical support at includes the ni.com/support following resources: – Self-Help Technical Resources—For answers and solutions,...
Page 71
Appendix B Technical Support and Professional Services • Declaration of Conformity (DoC)—A DoC is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety.
Page 73
Glossary Celsius. cache Small portion of high-speed memory used for temporary storage of frequently used data. CMOS Complementary Metal Oxide Semiconductor—A process used in making chips. CompactPCI Express An adaptation of the PCI specification for industrial and/or embedded applications that require a more robust mechanical form factor than desktop PCI.
Page 75
PXI backplane. A transfer can be either a read or a write. Megabytes of memory. MTBF Mean time between failure. NI-DAQ The National Instruments software for data acquisition instruments. NI-VISA The National Instruments implementation of the VISA standard—An interface-independent software that provides a unified programming interface for VXI and serial instruments.
Page 77
Glossary Universal Serial Bus. Volts. Video Graphics Array—The minimum video display standard for all PCs. Watts. NI PXIe-8101/8102 User Manual ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 81
Index front panel physical specifications, A-2 connectors, 3-1 POWER OK LED, 3-11 controller reset pushbutton, 3-11 Power/Reset Configuration menu, 2-9 dimensions, 3-2 programming examples (NI resources), B-1 features, 3-11 protective screw caps, removing (figure), 2-2 LEDs, 4-1 PS/2, plugging PS/2 mouse and keyboard into controller, 4-3 functional overview, 1-2 PXI chassis configuration, 2-23...
Page 82
2-22 damaged module, 5-2 LabVIEW, 1-4 NI resources, B-1 LabWindows/CVI, 1-5 video display, 5-2 Measurement Studio, 1-5 National Instruments software, 1-4 NI resources, B-1 Universal Serial Bus (USB), 3-9 NI-DAQmx, 1-5 connector, 3-1 NI-VISA, 1-6 function, 1-4...
Page 83
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the PXI Express Series and is the answer not in the manual?
Questions and answers