Diagnostic Manual (EMS)
Genio DC BS-III & BS-IV
Rail Pressure
Governor
Sensor Supply
Monitoring
Continuous
Torque
Monitoring
All copyrights reserved by
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes
introduced by the manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or
whole of the present document, are prohibited without the prior written consent of Mahindra & Mahindra Ltd.
at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution© 2010 Mahindra &
Mahindra Ltd.
Maximum positive deviation of rail pressure
P1192
Maximum positive deviation of rail pressure
P1193
exceeded concerning set value
Negative pressure deviation combined with the set
P1194
P1195
Minimum rail pressure exceeded.
P 1196
Minimum rail pressure exceeded.
P 1644
Error Sensor Supplier Monitor 1
P 1646
Error in Sensor supply Monitor 2
P 1648
Error in Sensor Supply Monitor 3
P 1900
NTP error in ADC monitoring
P 1901
Error in Sensor supply - APP
Error in plausibility of the test voltage in ADC
P1902
Error in plausibility of the ratiometry
P1903
correction in ADC monitoring
Error in the plausibility of the function
P1904
controller and the monitoring module.
P1905
Error due to interrupted SPI communication.
P1906
Multiple error in complete ROM test.
Too less bytes received by Monitoring
P0910
module from CPU as response.
Error in plausibility of the Accelerator pedal
P1907
Impermissible offset between the engine
P1912
speed of level 2 and level 1
P1913
ET plausibility check failure
Error in the plausibility of the start of
P1914
Error in the plausibility check of the ZFC
P1915
Error in the check of the shut-off path test of
P1911
the over voltage detection
P1908
Error trying to set the MM response
P1909
Expiration of waiting time due to hardware
P190A
P190B
Error in under voltage monitoring
P190C
WDA is not working correctly
Time out error trying to set or cancelling the
P190D
P190E
Time out error while requesting an injection
P190F
Time out error in shut off path
P1922
Visibility of software resets 2 in DSM
MAN-00139-16
August 2011/Rev 1
exceeded
value of PCV
monitoring
voltages
energizing angles
energizing times
Wrong MM time
not active
alarm task
The use of this document by any person other than the trained personnel,
81
84
85
86
87
89
90
91
92
96
97
98
95
time.
93
94
99

Advertisement

loading
Need help?

Need help?

Do you have a question about the Genio DC BS-III and is the answer not in the manual?

This manual is also suitable for:

Genio dc bs-iv