7.1 Changing the Vaporizer

The micro vaporizer especially developed for the Tiny S has a limited working life.
Depending on application duration, the fogging output will reduce after a while and
the vaporizer will need to be changed.

7.1.1 Removal of the Vaporizer

a) Separate the Tiny S from the battery. To remove the battery, press it slightly into
the slot, rotate it anti-clockwise and withdraw it.
b) Unscrew the four screws [3] with a suitable screwdriver to release the stainless steel
hood.
c) Remove the stainless steel hood.
d) Unscrew the two screws [6] at the vaporizer with a suitable screwdriver.
e) Slide out the vaporizer [7] forwards.
f) Remove the fluid tube [8] from the tubing spout [9] of the vaporizer. If the tubing
does not come off, you can pull on it with a pair of small pliers or a similar tool.
g) Clean the interior of the unit with an absorbant, fluff-free cloth.

7.1.2 Installation of the Vaporizer

a) Plug the fluid tube [8] onto tubing spout [9] of the new vaporizer.
b) Mount the new vaporizer to the connecting pins [10] with the two screws [6] .
c) Check the connections and make sure that the fluid tubing is not twisted or bent.
d) Mount the stainless steel hood with the four screws [3] at the machines cover. Ensure
that the hood engages into the corresponding guide groove of the lid part.