Toshiba Stratagy IVP8 Installation Manual page 38

Voice processing
Hide thumbs Also See for Stratagy IVP8:
Table of Contents

Advertisement

Installation
Step 11: Configure Stratagy IVP8
Table 3
Stratagy IVP8 System Configuration Parameters – Definitions and Settings (continued)
Parameter
dss_active
ksu_time
pbx_type
trace_cap
26
Stratagy IVP8 monitors the Busy Lamp Field (BLF) indicators on the Strata CTX/
Strata DK's DSS console port to determine if an extension is busy before attempting to
transfer. This parameter corresponds with the DSS Port field assignment in the Users
Option Menu of a User ID.
True:
Stratagy IVP8 monitors the BLF indicators before attempting to transfer a call.
False:
Stratagy IVP8 does not monitor the BLF indicators.
Important!
If this parameter is set to false, the DSS Port field on the Users Option
Menu is disabled.
Possible values: true, false
Default: false
Synchronizes Stratagy IVP8's system clock with the system clock of the supporting
Strata CTX/Strata DK telephone system.
Information obtained by Stratagy IVP8 from the Strata CTX/Strata DK system does not
contain "second" time; therefore, there may be a 1~60 second difference between the
Strata CTX/Strata DK system and the KSU time displayed on the main menu of the
Stratagy Admin program.
Important!
The Stratagy IVP8 electronically monitors the clock information on the LCD
of the defined PDKU port. If other LCD messages (e.g., message waiting
callback information) appear over the system time, the Stratagy IVP8 is
unable to consistently synch to the KSU time.
True:
Stratagy IVP8 synchronizes the Stratagy IVP8's system clock with the
Strata CTX/Strata DK's system clock. The KSU time displays at the top right
corner of the Main Menu. Setting this parameter to true, disables the
daylight_saving_time parameter.
False:
Stratagy IVP8 does not use the Strata CTX/Strata DK's system clock.
Important!
The Strata DK uses a 24-hour system clock, but does not notate a.m./p.m. on the
LCD display. Because of this, during the initial installation or when the system has
been shut down for any extended time, it is necessary to program the correct date
and time in the Stratagy IVP8 Main Menu, Date/Time function or via System
Administrator's mailbox.
This feature requires SMDI integration to work with the Strata CTX.
Possible values: true, false
Default: false
Defines the model of Strata CTX/Strata DK that is used as the host system.
Possible values: DK8, DK16, DK16E, DK24, DK56, DK96, DK14/40, DK14/40S
(DK24/40 with SMDI), DK280, DK280S (DK280 with SMDI), DK424i, DK424,
DK424S (DK424 with SMDI)
Default: DK424i/DK424
Defines the size of the TRACE.OUT file in kilobytes. When the size of the file reaches its
defined maximum, new data begins to overwrite the oldest data in the file, generating a
continuous loop of information.
Possible values: Values vary depending on the amount of Trace information required
and the space available on Stratagy IVP8's hard drive. If this value is
set high, it could take an excessive amount of time to copy the file to
the portable/desktop computer. A standard setting is 1440 for copying
the file to the portable/desktop computer's floppy-disk drive.
Default: 1000 (kilobytes = 1 megabyte)
Description
Stratagy IVP8 Installation Guide
01/02

Advertisement

Table of Contents
loading

Table of Contents