Summary of Contents for Thermo Scientific iEMS Incubator
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 9
List of Tables Table 5.1 Installation check list ................... 14 Table 6.1 Speed settings of the shaker ................22 Table 6.2 LED color codes ....................23 Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Other markings used in the documentation Note: Marks a tip, important information that is useful in the optimum operation of the system, or an item of interest. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Information and 11 Warranty Certificate. In an effort to produce useful and appropriate documentation, we appreciate your comments on this document to your local Thermo Fisher Scientific representative. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Extended temperature range • • Exceptional temperature uniformity across the plate • Efficient orbital shaking • Capacity of up to three (3) microplates Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
INC TIME 00:30:00 Fig. 4.4 iEMS Incubator/Shaker HT display The alphanumeric liquid crystal display (LCD) has two (2) lines with up to 20 characters per line. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Adjust the screws (Fig. 4.5, item 4) with a screwdriver so that the microplate is held firmly in place during shaking. Warning: Microplate holders will be hot when touched after use. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Use of alternative packaging materials may invalidate the warranty. Also retain all instrument-related documentation provided by the manufacturer for future use. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Use proper protective clothing. Use disposable gloves. Ensure the working area is well ventilated. Never spill fluids in or on the equipment. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
2. Use a small flat screwdriver to pry the voltage selector/fuse block assembly away from the power entry port housing and remove (Fig. 5.1). Fig. 5.1 Opening the voltage selector/fuse block assembly Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
3. Connect the instrument to a correctly installed line power outlet that has a protective conductor that is grounded. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
(24-hour clock). The baud rate is used for service purposes only. stop If you want to interrupt the setup, press to return to the READY state. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
50 ↵ Press INC TIME 00:00:00 Note: stop If you want to interrupt the programming, press to return to the READY state. Your changes will be saved. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Page 24
The value will be entered at the location of the cursor. For example, for an interval shaking time of zero: SHAKE TIME 00:00:20 00 00 ↵ Press (Enter) INT TIME 00:00:00 Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
PROHIBITED OPERATION appear on the display: READY 09:26:15 On the display, the READY state will appear after the programming phase. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
If you remove the thermal microplate holder and then reinsert it into the slot during the initial preheating of the slot. If the programmed target temperature is lower than the actual temperature • of the slot. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Avoid bumping the microplate holder while inserting it into the slot. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Note: If the thermal microplate holder is not latched into position, it may lose contact with the temperature controlling connectors at the rear of the slot. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
To minimize the likelihood of this occurring, it is recommended you program all processing protocols within a module with the same shaking speed. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
For example, if there is a protocol in progress with speed 5 and the adjoining slot is started with speed 3, all slots within the module will shake at speed 3. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
LED are turned off and the heating of the slot is turned off. 3. Re-insert the microplate holder into the slot. The orange LED is turned on and the heating of the slot turns back on. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Press . The instrument continues to shake until the programmed time of the other slots in the instrument has elapsed. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
All shaking and incubation functions, including timing, will be turned off. No LEDs will be lit and the current time of day will be shown on the display. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
OFF in all slots. READY 09:29:10 Press to return to the READY state. Warning: Microplate holders will be hot when touched after use. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
To stop shaking before the shaking time has elapsed: stop Press the slot number and the key. The protocol stops, the LED turns to green, and you will hear a beeping sound. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
When you review the parameters, ensure you do not make any unintentional changes to the programmed values. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
4. Place the fuse holder back into the slot and push it in until you hear a click. 5. Connect the power cable to the instrument and switch it ON. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
EIA tests in a negative way resulting in bad test results. Warning: Always use disposable gloves and protective clothing and operate in a well-ventilated area. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
RoHS Directive are available at www.thermo.com/WEEERoHS. Regarding the original packaging and packing materials, use the recycling operators known to you. For further information, contact your local Thermo Fisher Scientific representative. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Doing so might cause misalignment and will invalidate the instrument warranty. Do not operate the instrument in an environment where potentially damaging liquids or gases are present. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
During shaking Do not place the microplate holder in or remove it from the instrument while the instrument is shaking. This may damage the shaking mechanism. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
During shaking Do not place the microplate holder in or remove it from the instrument while the instrument is shaking. This may damage the shaking mechanism. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
The use of spraying may damage the instrument. If local or laboratory regulations prescribe regular decontamination, it is not advisable to use formaldehyde, since even small traces of formaldehyde affect Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
The Thermo Fisher Scientific technical service department will keep you up to date with the progress of service and provide you with any further details you might need, for example, on maintenance, serviceability, troubleshooting and replacement. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Maximum 86 mm (W) x 128 mm (L) x 15 mm (H) Device interfaces 1. Serial RS-232C interface for computer 2. Serial RS-485 interface for other device link Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
1 mm (radius 0.5 mm) Programmable shaking time Up to 48 hours in steps of 1 second Programmable interval time Up to 48 hours in steps of 1 second Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Both of these affect the dimensioning of the electrical insulation within the instrument. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
1210940 Fuse 3 A slow 1210550 Power cord, Euro (230 V) 1210520 Power cord, USA (100 V and 115 V) 5921210 iEMS thermal microplate holder HT Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Full warranty terms and conditions can be obtained from your local Thermo Fisher Scientific dealer. 11.1 Warranty limitations • Consumables are not included in the warranty. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Do not place the microplate holder in or remove it from the instrument while the instrument is shaking. This may damage the shaking mechanism. 11. Turn the instrument OFF. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
This unit is certified by the undersigned to be free of radioactive contamination. Date and place: Signature: Name (block capitals): PHOTOCOPIABLE Please include decontaminating solution used. Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Further instrument/system developments desired: Further applications desired: Where did you first learn about the product? Would you like to receive information about other Thermo Scientific products? Thermo Scientific iEMS Incubator / Shaker HT User Manual Rev. 2.4, Cat. no. 1506400A...
Page 65
Thermo Fisher Scientific Oy Microplate Instrumentation Ratastie 2, P.O. Box 100 FI-01621 Vantaa Finland www.thermo.com 1506400A...
Page 66
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the iEMS Incubator and is the answer not in the manual?
Questions and answers