Rite Rate Flow System (Continued)
4 . If the 20 AMP fuse is not blown, check the electrical connections:
A . Check that the Red wire connected to a key switched 12 VDC power source .
B . Check that the key switched 12 VDC power source is receiving power when the tractor key is in the operate/
run position . If it is not receiving power, contact your local farm equipment service center .
C . Check that the White wire is connected to a good tractor grounding point .
5 . If both fuses are blown, there may be an issue with the tractor's electrical system . Contact your local farm equipment
service center .
6 . Was the tractor jump started, welded on, or connected to a battery charger and the Raven SCS660 NVM power
connections still connected? If yes, the Raven SCS660 NVM may have received some internal electronic damage .
Contact Balzer's Service Department at 1-800-795-8551 Ext . 134 (or press 0 for the operator) .
Raven SCS660 NVM Not Controlling Flow Properly
1 . Check the Raven SCS660 NVM programming . If the programming is not correct, see "Rite Rate Flow System
Programming" .
2 . If the programming is correct, check all connections between the Raven SCS660 NVM Controller and the
A . Krohne Optiflux 4100C
B . Raven 660 PWM Boost Box and down pressure block
C . Sky Trak GPS
3 . Check if the Sky Trak GPS has an unobstructed view of the sky and check GPS on another GPS capable device (a
GPS enabled highway navigation system, such as Garmin or TomTom, or a cellular telephone with GPS capabilities) to
see if that device is able to obtain a GPS signal . GPS systems require communication with at least four GPS satellites .
4 . Check the 1 AMP Blade Fuse that is inline with the Power Cable connected to the Krohne Flow Meter .
5 . If the 1 AMP fuse is not blown, check for voltage at the fuse . If no voltage is present, recheck all connections between
the flow meter and the Raven SCS660 Controller .
6 . Check that the gate valves are open when the system is operating .
7 . Check that the pump is operating properly .
8 . If the flow is still not being properly controlled, call Balzer's Service Department at 1-800-795-8551 Ext . 134 (or press
0 for the operator) .
Rite Rate Flow System Programming
When programming data into console, press the desired data key, press enter, press the numbers, then press enter to accept .
Example: To program the Valve Cal
VALVE
1 . Press Valve Cal
ENTER
2 . Press Enter
3 . Enter the numeric value (IE: 43 -
ENTER
4 . Press Enter
Rite Rate Flow System Programming/Reprogramming Steps:
1 . Turn Power on (if the display doesn't show US VOLUME, turn off the controller, then press and hold
the controller on .)
ENTER
2 . Press
to accept US - VOLUME
CE
3 . Press
until the display shows to SP2 - RADAR, then press
ENTER
4 . Press
to select LIQUID SPRAYER
CE
5 . Press
until the display shows C-PC-PWM CLOSE VALVE, then press
44
CAL
6
SPEED
BOOM
CAL
CAL
4
3
)
TROUBLESHOOTING
ENTER
ENTER
Eliminator Vacuum Tank (Tandem) User Manual
CE
while turning