Rite Rate Flow System Field Operation

Pre-Operation Checks
1 . Check the hydraulic connections .
2 . Before starting the tractor, check all electrical connections at the Raven SCS660 NVM Controller and at the hitch .
3 . Start the tractor and turn the Raven SCS660 power ON and leave the MASTER switch in the OFF position . The display
on the Raven should light up .
4 . Check to see if the Krohne Optiflux Flow Meter is receiving power .
5 . Confirm the Raven has the correct programming (if incorrect, see "Rite Rate Flow System Programming" on Page
44) .
6 . Check to see that the SPEED CAL has been set to 598 .
7 . Check the BOOM CAL to see if it is correctly programmed with the proper width (in inches) of your plow/injector
toolbar) .
8 . Check the application rates programmed into RATE 1 CAL and RATE 2 CAL . If you desire, you can zero out any totals
showing for TOTAL VOLUME, TOTAL AREA, etc .
9 . With the tank empty, engage the hydraulics to lower the injector and start the slurry pump . The injector down pressure
will be applied but the discharge valve will not open and the pump will not turn with the MASTER switch in the OFF
position . Check the pressure gage at the block to ensure proper down pressure for the injector .
10 . Disengage the hydraulic down pressure and lift the injector up .
11 . Fill the slurry tank .
12 . On the way to the field, check the speed calibration by pressing the
reasonably accurate when compared to the tractor's speed .
Field Application
1 . Upon arrival at the field, make sure the Raven SCS660 has the POWER turned ON . Set the Flow Control switch to
RATE 1 or RATE 2 for your desired application rate . Leave the MASTER switch OFF .
2 . Engage the hydraulics to lower the injector and apply down pressure .
Eliminator Vacuum Tank (Tandem) User Manual
Preprogrammed or
Manual Flow Control
POWER
FLOW CONTROL
ON
RATE 1
INC
RATE 2
OFF
MANUAL
DEC
BOOM
SPEED
METER
CAL
CAL
CAL
1
2
3
4
TOTAL
TOTAL
FIELD
FIELD
CE
AREA
VOLUME
AREA
VOLUME
Figure 27
Manual Flow Control
Override for Custom
Spot Application
VALVE
RATE 1
RATE 2
VOL
TIME
CAL
CAL
CAL
TANK
5
6
7
8
9
0
VOL /
AREA /
DATA
DISTANCE
SPEED
MIN
MIN
MENU
Disconnect power to the Raven SCS660 NVM
Controller before jump starting, welding, or charging
the battery.
SPEED
Controls Power to
the Raven 660 PWM
Boost Box .
MASTER
ON
Data Display
OFF
Screen
SELF
TEST
ENTER
Enters the Inputted
Information into the
Console
button . The speed displayed should be
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents