Vacuum Pump Automatic Oiler Adjustment (Continued)
4 . Use a short screwdriver and a 10mm wrench to adjust the oil flow . Rotate the adjustment screw 1/2 turn . Adjusting the
screw clockwise will decrease the drip rate and adjusting counter-clockwise will increase the drip rate .
5 . Check the oil drip rate after each 1/2 turn adjustment and continue adjusting if necessary . The drip rate should be
between 15 and 20 drops in 30 seconds .
6 . Replace the adjustment screw caps when the proper drip rate has been achieved .
7 . Replace the oil pump shield .