6.4.2
Alignement
To align the doors, open the doors and slightly unscrew the
set screws on the lower and upper door hinges with a 3/32"
Allen key to release the adjustable hinge rods.
Doors position
with more space
Left
Top
pintle
Bottom
pintle
6.4.3
Gasket
It is important to replace the gasket with another having the same diameter and density to
maintain a good seal.
1.
Remove the door and place it face-down on something soft.
2.
Remove the old gasket (L) from the door. Use a screwdriver to scrape the old gasket adhesive
from the door gasket groove.
3.
Also remove the screws (I), the retainers (J) and the door middle gasket (K).
Page 26
Using a flat screwdriver, turn the adjustable hinge rods in the directions
shown to adjust the doors. Tighten the set screws on the door hinges
when they are in the desired positions.
Doors position
with less space
Right
Left
Doors tilt up
Right
Left
Right
Installation and Operation Manual - Stratford II
3/32"
Doors tilt down
Left
Right