Osburn STRATFORD II OB04007 Installation And Operation Manual page 42

Table of Contents

Advertisement

• For installations where more than one chimney is located in the same non-chase or within the
same area, their terminations must be separated by at least 16" (410 mm) horizontally, and
18" (460 mm) vertically. This separation is to prevent smoke migrating from one chimney to
another.
• Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to
provide a 2" (50 mm) minimum clearance between the chimney and any combustible materials.
Do not fill this 2" space with insulation or any other combustible material.
• In all cases, the chimney must start with a 6" diameter anchor plate attached to the fireplace.
• If the male anchor plate nozzle exceeds 2" (50 mm) in length (A), it must be cut above the
lifting hooks welded inside the flue outlet so that it is sitting perfectly on the top of the
fireplace.
Page 42
Installation and Operation Manual - Stratford II