Programming Parameter
Up Slope
This parameter operates in (4T)
TIG modes only and is used to
set the time for the weld current
to ramp up, after the torch trigger
switch has been depressed then
released, from INITIAL CUR to
PEAK or BASE current.
Base Current
This parameter sets the current
at AC or DC TIG mode, and the
lowest current at DC or AC pulse
TIG mode. This parameter also
sets the STICK weld current.
Peak Current
This parameter sets the PEAK
weld current when in DC or AC
Pulse TIG mode.
Pulse Width
This
parameter
sets
percentage on time of the PULSE
FREQUENCY for PEAK weld
current when in DC or AC Pulse
TIG mode.
Pulse Frequency
This parameter sets the PULSE
FREQUENCY when in DC or AC
Pulse TIG mode.
Down Slope
This parameter operates in 4T
TIG modes only and is used to
set the time for the weld current
to ramp down, after the torch
trigger switch has been pressed,
to crater current. This control is
used to eliminate the crater that
can form at the completion of a
weld.
TIG (GTAW) Welding
Adjustment
Device
the
5-6
Display
Range: 0.0 to 15.0 seconds
Range:
10 to 205 Amps (DC and AC
TIG mode)
10 Amps to peak current (DC
and AC Pulse TIG mode)
Range: 10 to 205 Amps
Range: 10 to 90%
Range: 0.2 to 200 Hz
Range: 0.0 to 25.0 seconds
Factory Setting
1 second
80 Amps (DC TIG
mode)
100 Amps (AC TIG
mode)
50 Amps (DC Pulse
and AC Pulse TIG
modes)
100 Amps (DC Pulse
and AC Pulse TIG
modes)
50% (DC Pulse and
AC Pulse TIG modes)
1 Hz
1 second
0-5555