Nice NEOSTAR T Series Instructions And Warnings For The Fitter page 5

Tubular motor
Hide thumbs Also See for NEOSTAR T Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
5) What to do if...
a brief troubleshooting guide!
During the UP phase, before reaching the "0" position, the
motor stops and then makes 3 attempts to start up again.
This does not necessarily mean trouble: in case of overload during
the UP phase the motor is switched off for 1 second and then makes
3 attempts to complete the manoeuvre.
During the DOWN phase, before reaching the "1" position,
the motor stops.
This does not necessarily mean trouble: in case of overload during
the DOWN phase the motor is switched off.
During the DOWN phase the motor makes only half a rev-
olution, while in the UP phase it appears to turn normally
You must allow the UP manoeuvre to be completed to enable the
limit switch system to realign its position to "0"
6) Technical characteristics of the NEOSTAR_T tubular motors
Supply voltage and frequency
Current and power
Torque and Speed
Continuous operating time
Work cycle
Protection class
Operating temperature
Precision (resolution) of the electronic limit switch : greater than 0.55° (depending on the NEOSTAR_T version)
Nice S.p.a. reserves the right to modify its products at any time without notice.
Though an electrical phase is supplied with power, the
motor does not turn.
Check to see if the overload protection has triggered (in this case just
wait for the motor to cool down); then make sure that the motor is
powered at the correct mains voltage, measuring between the Com-
mon wire and the supplied electrical phase; finally try powering the
opposite electrical phase. If the motor still does not turn something
might be seriously wrong with the electronic switch control unit or
the motor windings.
: See the technical data on the label attached to each model
: See the technical data on the label attached to each model
: See the technical data on the label attached to each model
: maximum 4 minutes
: maximum 20%
: IP 44
: -10 ÷ 50 °C
GB
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neostar mtNeostar stNeostar lt

Table of Contents