Setting The Weight To Dispense; Setting Active Slide Gate; Auto Reset Function; Control System Compliance Information - Meridian Seed Express 275 DX Operator's Manual

Bulk seed tender
Table of Contents

Advertisement

Tare (12)
To "Tare" or zero the scale when the receiver
display is on the main display page showing the
weight, press and hold the tare push button on
either the remote transmitter or the receiver for
three seconds. The display will then show the
weight as zero.
LCD Display (13)
Turning key switch (1) to the ON position will turn
the LCD backlight ON. It will stay on until the key
is turned to the OFF position.

5.3.2 Setting the Weight to Dispense

1. Select the Weight To Dispense screen using
scroll button (11).
2. Press and hold Tare button (12) for five 
seconds.
3. The first character of the weight will start 
blinking.
4. Use the Increase (9) or Decrease (10) buttons
to select the appropriate number.
5. Use the Scroll button to move to the next digit.
Use the Increase (9) or Decrease (10) buttons
to select the appropriate number. Repeat this
until the desired weight has been entered.
6. Finally, holding the Tare button for another five 
seconds to save the new weight.
NOTE: The weight of the seed is calculated
when it is inside the compartments and as it flows 
through the slide gates. Any seed in the seed pan
or the conveyor has already been weighed and
does not affect the total weight.

5.3.3 Setting Active Slide Gate

1. Select the Active Slide Gate screen using
scroll button (11).
2. Use the Increase/Decrease buttons to set the
slide gate to either #1 or #2.
3. When the Auto Reset button is pressed on the
remote transmitter, the slide gate selected will
open automatically.

5.3.4 Auto Reset Function

1. Using the Weight To Dispense screen, select
the desired weight of the seed to be delivered
to the planter.
2. Using the Active Slide Gate screen, select
either the compartment 1 (Slide Gate 1) or the
compartment 2 (Slide Gate 2).
3. Press the Auto Reset button on the remote
transmitter. The unit monitors the weight
of seed being dispensed. As the weight
approaches the desired Weight To Dispense,
the slide gate will begin to close. If the weight
stops changing too soon, the unit will open the
slide gate slowly in order to get the desired
amount.
5.3.5 Control System Compliance
Information
This equipment has been tested and found
to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference. This
equipment generates radio frequency energy
and if not installed and used in accordance with
the instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to the reception of other
electronics, which can be determined by turning
the equipment off and on, DO NOT operate this
equipment around those devices.
This equipment has been certified to comply with 
the limits for a Class B computing device, pursuant
to FCC Rules. In order to maintain compliance
with FCC regulations, shielded cables must be
used with this equipment. Operation with non-
approved equipment or unshielded cables is
likely to result in interference to electronic device
reception. The user is cautioned that changes and
modifications made to the equipment without the 
approval of the manufacturer could void the user's
authority to operate this equipment.