2. Remove the rain collector
cone.
3. Using a Phillips-head
screwdriver, remove the three
screws connecting the rain
collector base to the threaded
spacers.
4. While removing the screws,
support the radiation shield
from the bottom. When the
screws are removed, it will
drop.
5. Take note of the cable
placement and routing so you
can replace it correctly.
6. Unscrew the three
threaded spacers
holding the solar
bracket and
radiation shield
together and lift off
the solar bracket.
7. Remove the two
cap plates.
36
Bracket
Solar Panel
Bracket
Closed Cap Plate
Open Cap Plate
(hole in center)
Stand-offs
1-1/4" Screw
Lock Washer
Flat Washer
Rain Collector Base
Threaded
Spacer
Threaded
Spacer
Lock Washer
Flat Washer
Solar Panel
Cable
(Plugged into
Junction Board)
Temp/Humidity
Cable
Junction Board
Fan Plate
Plates
Screen