Clear Data Collected During Testing and Installation
Now that the sensor suite is mounted outside, any data that was collected in the
Vantage Pro2 console during testing and mounting can be cleared.
1. On the console, press the WIND so that graph icon appears adjacent to the wind
data on the display. Confirm that wind speed is displayed on the compass rose.
2. Press and release 2ND, then press and hold CLEAR for at least six seconds and
until you see "CLEARING NOW" in the console ticker display.
Additional Mounting Options
Add-on Sensors: Use a Solar- or AC-Powered Sensor Transmitter (#6332 and
6331) to collect data from additional sensors and send it directly to your receiver
instead of plugging into the sensor suite. Each transmitter can support one each of up
to five sensors: Anemometer, Temperature Probe or Temperature/Humidity, Rain
Collector, UV, and Solar Radiation. This allows you to install your anemometer
remotely or add on a temperature station, for example.
Add a Wireless Leaf & Soil Moisture/Temperature Station (#6345):
See your garden or agricultural data on your console.
Extend Wireless Transmission Range: Optional solar-powered repeaters can
be used to extend the wireless transmission range. Choose a Standard Wireless
Repeater (#7627) or Long-Range Wireless Repeater (#7654).
Use Cables for Remote Mounting:
Note:
Not all cables are compatible with your Vantage Pro2 system. To be sure they will work,
order Davis extension cables from your dealer or directly from Davis Instruments.
Cabled Console:
from the console by using Davis Instruments extension cables (#7876).
Anemometer:
suite by using Davis Instruments extension cables (#7876).
Be aware that the maximum measurable wind speed reading decreases as the total
length of cable from the anemometer to the sensor suite increases.
Note: If the cable length is greater than 540' (165m), the maximum measurable wind speed
may be less than 100 MPH (161 km/h).
Solar Radiation and UV Sensors:
a 3' (0.9 m) cable. If you wish to install these sensors away from the sensor suite, you
can extend the length of the sensor cables up to 125' (38 m) with Davis Instruments
extension cables (#7876).
For more details, please visit our website or see the most recent Davis Precision
Weather Instruments catalog.
32
A cabled sensor suite can be extended up to 1000' (300 m) away
The anemometer can be extended further than 40' from the sensor
The solar radiation and UV sensors have

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vantage Pro2 Sensor Suite and is the answer not in the manual?

This manual is also suitable for:

Vantage pro2 plus sensor suiteVantage pro2 groweather sensor suite

Table of Contents

Save PDF