• All Vantage Pro2 stations include a 40' (12 m) cable to go between the sensor
suite and the anemometer. This can be extended up to 540' (165 m) using optional
extension cables purchased from Davis Instruments.
If most of the anemometer cable length is unused, the coiled cable length can be
stowed once the anemometer and sensor suite have been installed on a site. You
can secure the cable to the pole using the shorter cable ties. Use the longer cable
tie to secure the coil by running it through the holes on the rain collector shelf.
Keep the anemometer cable coiled if possible during the sensor suite and
anemometer assembly so that it is easily stowed once installation is complete.
• The Cabled Vantage Pro2 includes a 100' (30 m) cable to go between the console
and the sensor suite. This can be extended up to 1000' (300 m) using optional
cables.
Anemometer
Cable
Longer
Cable Tie
Shorter
Cable Tie