17.
Replace back mounting bracket & re-install (2)
screws with 5/16" nut driver.
21.
Replace head cover & re-install (4) screws.
19.
Finish sliding faceplate onto device.
Select your preferred torque mode (ships in standard torque) Press the device push pad to the
Step 1-
desired setting. (Recommend to fully depress and release 5%, giving the device room for
changing door conditions.)
While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 2-
Continue to keep pad depressed, the device will beep 6 times. After the beeps have
Step 3-
stopped, release the pad and now the adjustment is complete. If not to your liking repeat the
three steps.
Once you found the correct location, flip the dip switches to off to lock programming.
Step 4-
U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w . c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2
S
crewS
Setting PTS
18.
Replace front mounting bracket.
Connect to power (1) and push down on bar (2).
20.
Follow Push to Set instructions directions below,
remembering to turn the Programming Switch to the
off position when completed.
1.
2.
MM4 SWITCHES
OFF
1
STANDARD TORQUE
ON
HIGH TORQUE
ON
2
pts programming on
OFF
pts programming off