MM4 SWITCHES
OFF
1
STANDARD TORQUE
ON
HIGH TORQUE
ON
2
pts programming on
OFF
pts programming off
Step 1-
Select your preferred torque mode (ships in standard torque) Press the device push pad to the
desired setting. (Recommend to fully depress and release 5%, giving the device room for
changing door conditions.)
While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 2-
Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release
Step 3-
the pad and now the adjustment is complete. If not to your liking repeat the 3 steps.
Once you found the correct location, turn PTS switch to OFF position.
Step 4-
Troubleshooting & Diagnostics
Explanation
Beeps
2 Beeps
Over Voltage
Under Voltage
3 Beeps
4 Beeps
Failed Sensor
5 Beeps
Retraction or dogging failure
6 Beeps
PUSH TO SET
U S c u s t o m e r s u p p o r t 1 - 8 8 8 - 6 2 2 - 2 3 7 7 | w w w . c o m m a n d a c c e s s . c o m | C A c u s t o m e r s u p p o r t 1 - 8 5 5 - 8 2 3 - 3 0 0 2

Technical Information

SPECIFICATIONS

Input Voltage: 24VDC +/- 10%
Wire gauge: Minimum 18 gauge
Direct wire run - no relays or access control
units in-between power supply & module
Setting PTS
**Important Info**
Make sure to set PTS before finishing installation
> 30V unit will shut down. Check voltage & adjust to 24 V.
< 20V unit will shut down. Check voltage & adjust to 24 V.
Verify all 3 sensor wires are installed correctly. Replace sensor if problem
After 1st fail: 5 beeps then immediately attempts to retract again.
After 2nd fail: 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.
Device is recording it's new position and power mode after the 6th beep.
Solution
persists by contacting office.
To Reset: Depress bar for 5 seconds at any time.
Standard Torque Mode
Average Latch Retraction Current: 900 mA
Average Holding Current: 215 mA
High Torque Mode
Average Latch Retraction Current: 2 Amp
Average Holding Current: 250 mA