NEC QX-S5500G Series Installation Manual page 101

Table of Contents

Advertisement

Installation Guide
QX-S5500G Series Ethernet Switches
Load File Name
Server IP Address
Local IP Address
Subnet Mask
Gateway IP Address
 NOTE:
To use the default setting for a field, press Enter without entering any value.
If the switch and the server are on different subnets, you must specify a gateway address for the switch.
4)
Enter all required parameters and press Enter to start downloading the file.
Loading.................................................Done!
5)
Enter Y at the prompt to upgrade the basic Boot ROM section.
Will you Update Basic BootRom? (Y/N):Y
Updating Basic BootRom...........Done.
6)
Enter Y at the prompt to upgrade the extended Boot ROM section.
Updating extended BootRom? (Y/N):Y
Updating extended BootRom.........Done.
7)
Enter 0 in the Boot ROM update menu to return to the Boot menu.
1. Update full BootRom
2. Update extended BootRom
3. Update basic BootRom
0. Return to boot menu
Enter your choice(0-3):
8)
Enter 0 in the Boot menu to reboot the switch with the new Boot ROM image.
II. Using FTP to upgrade Boot ROM through the Ethernet port
1)
Enter 6 in the Boot menu to access the Boot ROM update menu.
1. Update full BootRom
Table 6-8 TFTP parameter description
Item
Name of the file to download (for example, update.btm).
IP address of the TFTP server (for example, 192.168.0.3).
IP address of the switch (for example, 192.168.0.2).
Subnet mask of the switch (for example, 255.255.255.0).
IP address of the gateway (in this example, no gateway is required
because the server and the switch are on the same subnet).
Description
6-30
6. Upgrading software