pH Monitoring (Optional)-
Ecowater has chosen to utilize an industrial pH probe for this measurement.
A pH meter is an
electronic instrument used for measuring the pH (acidity or alkalinity) of a liquid. The pH probe
measures pH as the activity of hydrogen cations surrounding a thin-walled glass bulb at its tip. The
probe produces a small voltage (about 0.06 volt per pH unit) that is measured and displayed as pH units
by the CHC Control Station (CHCCS). The pH probe is a combination electrode, which combines both
the glass and reference electrodes into one body. It is important that this probe be clean and calibrated
at regular intervals, please refer to the appropriate sections of this manual for specific information.