10BASE-T EXTENDER
Table 3-1. Maximum resistance values of other wire gauges.
Gauge
24GA
22
20
18
Wire smaller than 24 gauge is not recommended, and any wire used
must be 100-ohm impedance, unshielded twisted pair.
Telephone wire connected between two Extender units may span up to 600 feet
(272 m) in length.
3.8 Install 10BASE-T Extenders
Follow these steps to set up the Extenders:
1. Install the Extender in the wiring closet near the punchdown block or patch
panel. You can mount it with the Velcro
2. Plug the power supply into the wall and attach it to the Extender.
3. Observe the LEDs on the Extender.
• The green power LED will be on.
• The LZ6000A-R3 is shipped with the Link Integrity Test set to ON (enabled).
When power is connected, the Link Test indicator should not light, showing
that the link is not yet established. After connecting to a 10BASE-T line, the
indicator will light amber, indicating a "good link." Check the manual that
came with the 10BASE-T device that you are connecting to. If it requires Link
Integrity Test to be OFF, move the jumper so it covers only one pin (see
Figure 3-9). This will set the Link Integrity to OFF and the indicator on the
face of the unit will not be lit.
16
Maximum Resistance (for 600 ft. [272 m])
30 Ω
19
12
7.5
NOTE
®
strip provided.