Events Reporting
•
Event Types: Digital Input, GPS/AVL, Network parameters, Data usage,
Timer, Power, Device temperature
•
Report Types: SMS, Email, SNMP Trap, Relay output, GPS RAP report,
Events protocol message to server
VPN/Security
•
IPsec, SSL, and GRE VPN client
•
Up to 5 VPN tunnels
•
IKE encryption
•
Port forwarding and DMZ
•
Port filtering
•
Trusted IP
•
MAC address filtering
Device Management
•
AirVantage™ Management Service cloud-based device management appli-
cation
•
ACEManager™ device configuration utility
ALEOS Application Framework
•
Lua language coding platform
•
Remote application management
•
Eclipse-based IDE
•
Integrated real-time debugging
Power Consumption
All values in mA @ 12VDC
•
HSPA+: Idle: 224, Typ 245, Max 430
•
CDMA: Idle 220, Typ 257, Max 427
•
Low power standby mode: < 68
•
Analog Ignition Sense and Power Management
•
Input Voltage: 7–28 VDC
Environmental
•
Operating temperature: -30°C to +70°C (-22°F to +158°F)
•
Storage temperature: -40°C to +85°C (-40°F to +185°F)
•
Humidity: 90% RH @ 60°C (140°F)
•
Military Spec MIL-STD-810 conformance to thermal, mechanical shock, and
humidity