The channel type baling
press must not be taken into
operation if the condition of
the connection cable is not
Current, plugged connections, check condition
Put main switch in "0"
position before opening the
• Inspect plugged connections for obvious
damages as e.g. corrosion etc.
• The damaged plugged connections have
to be replaced immediately by a qualified
electrician.
proper.
switch box.
04/2012
Check hydraulic oil level
• First drive press ram into open limit stop
Prior to the start of this
work put main switch into
"0" position and secure
• Check the hydraulic part of the aggregate
for tightness (visual inspection).
• Screw out tank ventilator.
• Check run-in hydraulic cylinders if the
distance between liquid level and upper
edge of the screwed socket is not more
than 4 - 5 cm.
• Refill hydraulic oil as required. You will
find information with regard to the used
hydraulic oil in the section "Operating
fuels, specifications".
• See to cleanness in the area of the tank
ventilator. Retighten tank ventilator.
If no further maintenance works have to be
carried out in this area, replace removed
protective covers again and retighten
properly.
7 - 10
with a padlock.