Superabrasive
4. OPERATION
PRELIMINARY CONTROLS
Inspect the working area as explained in the safety instructions. For wet use, fill in the water tank when the electrical cable is
disconnected. Connect the vacuum extractor and ensure that the vacuum hose is clear and it will follow the machine easily. Plug in
the machine and make sure that the power cord is free to follow the working direction of the Lavina®25LM‐S‐E machine.
WATER FLOW CONTROL UNIT
The operator can choose the water sprayer in the front when the tap is in the horizontal position (Fig.4.1), the water will
Figure 4.1
ADJUSTING AND MOUNTING TOOLS
Mount the tools only after ensuring that there is enough diamond bond material left. Be sure that the plates are always clean
WARNING:
before mounting.
(Fig.5.3). Diamond tools with Velcro are attached on three 9 inch foam plates (Fig4.4). The foam plates are mounted on the key lock
(butterfly). Always use the tool holder key (Fig.5.3).
Figure 4.5
User Manual
Figure 4.2
Always secure the "QuickChange" pads with the security plate (Fig.4.3), lock with the tool holder key
FRAME BLOCKING (U‐JOINT]
The relation between the working head and trolley is the frame (U‐joint), which allows rotation about
two perpendicular axes to better follow the profile of the floor.
The move ment along the one axis can be fixed with two screws (Fig.4.5) and that block the lateral
movement of the machine.
Original Language
spray under the cover of the machine when
the level is in the vertical position
(Fig.4.2).The flow regulating valve located on
the tank (Fig.4.2.1) is increasing or reducing
the water flow to the working area – in front
of the machine or under the main head cover
of the machine/only for machines produced
afterJan.1 2014/.
Figure 4.2.1
Figure 4.3
7
Lavina® 25LM‐S‐E
Figure 4.4
12/2014