Troubleshooting; Index Of Problems And Solutions; Replacing Power Cord And Plugs - lavina L25LM-S-E User Manual

Table of Contents

Advertisement

Superabrasive 
 
9. TROUBLESHOOTING 
INDEX OF PROBLEMS AND SOLUTIONS 
9.1 REPLACING POWER CORD AND PLUGS  
When replacing the power cord or plugs, always use cords and plugs with the exact specifications as the original ones. Never use 
lower quality or different types of cords or plugs.  
In addition, take into consideration the distance of the application from the electrical source. The grater the distance, the greater the 
resistance and the less current that will be available at the other end, there will be a voltage drop and the inverter will go into alarm 
mode. This also happened if several machines are working on the same line or when the generator is underrated. In general, our 
standard cable can be doubled in length, if a longer length is needed you can replace all the cables with cables of a bigger gage rated 
for the length and the amperage.  
9.2 DISMOUNTING AND MOUNTING TOOL HOLDER TO CHANGE BUFFERS AND SPIDER, CHANGING V‐RINGS AND FELT‐RINGS 
Figure 9.2.1
 
 
Figure 9.2.4
To check or place the buffers and the spiders, the tool holder has to be dismounted. Remove the countersunk screws on top of the 
buffer (Fig.9.2.1). Take the disc off (Fig.9.2.2), the spider can be removed or replaced (Fig.9.2.3). By loosening the four Hex cap bolts 
(Fig.9.2.4), the disc comes loose (Fig.9.2.5) and the buffers can be replaced (Fig.9.2.6). Attention, when mounting, always use the "blue" 
thread locking adhesive, except on the bolts to lock the buffers (Fig.9.2.5). Always use original bolts. Depending on the number (3, 4, or 
6) of buffers, the holder can be more flexible or rigid.  
 
 
 
 
 
 
 
 
 
 
Figure 9.2.7
 
When the tool holder is dismounted, you can change the sealers (V‐Ring and Felt‐Ring). Take out  
felt‐ring, Adaptor and V‐Ring. Before mounting check on which side the adaptor is fitting, 
remember the correct side. Mount the V‐Ring with the smallest lip of the V to inside (Fig.9.2.7) 
just push the V‐ring so the top is on the same level  as the pulley top (Fig.9.2.8). Then take the 
adaptor in the correct way and push the V‐Ring down with the adaptor (Fig.9.2.9). The lowest lip 
of the V‐Ring should only barely touch its gliding surface; also never  push the V‐Ring down with 
fingers. Mount now the felt‐ring  on top (Fig.9.2.10). Close the sealers with the cap (Fig.9.2.11). 
 
User Manual  
 
Figure 9.2.2
 
Figure 9.2.5
Figure 9.2.8
Original Language 
Figure 9.2.9
15 
Lavina® 25LM‐S‐E   
 
Figure 9.2.3
 
Figure 9.2.6
Figure 9.2.10
Figure 9.2.11
 12/2014 
 
 

Advertisement

Table of Contents
loading

Table of Contents