INSTRUCTION BULLETIN
NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts
List in the appropriate place in your machine manual for future reference.
Retaining the Parts List will make it easier to reorder individual parts and will
save you the cost of ordering an entire kit.
NOTE: Numbers in parenthesis ( ) are reference numbers for parts listed in Bill of Materials.
Installation instructions for kit number 375429, 375430 and 375431
SYNOPSIS / PROBLEM:
This kit contains the parts needed to replace the solution and recovery tank level switches
on the models 7100/7200, 8200/8210 and 7300/8300 scrubbers and sweeper/scrubbers.
Please follow step-by-step instructions.
SPECIAL TOOLS / CONSIDERATIONS: Metri- -Pac wire test harness, voltmeter
(Estimated time to complete: 1 hour)
PREPARATION:
(Refer to FIG. 1 thru 7)
FOR SAFETY: Before leaving or servicing machine, stop on level surface and set parking
brake. Then turn off machine and remove key.
1. Disconnect battery cables from machine.
WARNING: Always disconnect battery cables from machine before working
on electrical components.
SOLUTION TANK PRESSURE SWITCH REPLACEMENT, 7100:
(Refer to FIG. 1)
1. Open the tank cover on the rear of the machine and locate the pressure switch 385732 and
34 inch tube 386966 on the top of the solution tank.
2. Disconnect the old pressure switch from the main wire harness.
3. Remove and discard the old pressure switch and tube from the solution tank.
NOTE: Lubricate the tube switch assemblies and hoses with a small amount of liquid soap for
easier installation.
4. Install the new tube/switch assembly 375428 in the solution tank switch opening.
(Refer to FIG. 1)
5. Connect the new tube/switch assembly 375428 to the main harness. Close the tank cover.
Check the new switch for proper operation.
IB 340487 (6-01) LITHO IN U.S.A.
No. 340487
Machine: 7100,7200,7300
8200,8210,8300
Published: 6-01/00
System: SCRUBBING
(Refer to FIG. 1)
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 7200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tennant 7200

  • Page 1 SYNOPSIS / PROBLEM: This kit contains the parts needed to replace the solution and recovery tank level switches on the models 7100/7200, 8200/8210 and 7300/8300 scrubbers and sweeper/scrubbers. Please follow step-by-step instructions. SPECIAL TOOLS / CONSIDERATIONS: Metri- -Pac wire test harness, voltmeter...
  • Page 2 Replace 385732 and 386966 w/ 374428 FIG. 1 - - SOLUTION TANK PRESSURE SWITCH INSTALLATION, 7100 IB 340487 (6-01) LITHO IN U.S.A.
  • Page 3 RECOVERY TANK PRESSURE SWITCH REPLACEMENT, 7100: (Refer to FIG. 2) 1. Remove and set aside the tank cover, cable and mounting bolts. 2. Disconnect the vacuum fan from the main harness. Remove and set aside the vacuum fan and mounting hardware. 3.
  • Page 4 RECOVERY TANK PRESSURE SWITCH REPLACEMENT, 7200: (Refer to FIG. 3) 1. Remove and set aside the tank cover, cable and mounting bolts. 2. Disconnect the vacuum fan from the main harness. Remove and set aside the vacuum fan and mounting hardware.
  • Page 5 Replace 385732 and 385744 w/ 375426 FIG. 3 - - NEW RECOVERY TANK SWITCH INSTALLATION, 7200 IB 340487 (6-01) LITHO IN U.S.A.
  • Page 6 RECOVERY TANK PRESSURE SWITCH REPLACEMENT, 8200/8210: (Refer to FIG. 4 and 5) 1. Open the engine cover, and the engine side door. 2. Remove and set aside the engine cover support bracket to access the float switches on the recovery tank. (Refer to FIG.
  • Page 7 Replace 385732 and 385744 w/ 375426 Solution tank Replace 385747 and 385730 w/ 375427 Recovery tank FIG. 5 - - SOLUTION AND RECOVERY TANK PRESSURE SWITCH INSTALLATION, 8200/8210 IB 340487 (6-01) LITHO IN U.S.A.
  • Page 8 RECOVERY TANK PRESSURE SWITCH REPLACEMENT, 7300/8300: (Refer to FIG. 6) 1. Open the recovery tank cover, and locate the float switch 385732 and 8 inch tube 375744. 2. Disconnect and remove the float switch 385732 and 8 inch tube 385744 from the recovery tank.
  • Page 9 Replace 385732 and 385744 w/ 375426 FIG. 6 - - SOLUTION TANK PRESSURE SWITCH INSTALLATION, 7300/8300 IB 340487 (6-01) LITHO IN U.S.A.
  • Page 10 SOLUTION TANK PRESSURE SWITCH REPLACEMENT, 7300/8300: (Refer to FIG. 7) 1. Open the solution tank cover, and locate the float switch 385732 and 34 inch tube 386966. 2. Disconnect and remove the float switch 385732 and 34 inch tube 386966 from the recovery tank.
  • Page 11 Switch assy, dual press, 14” tube BILL OF MATERIALS FOR ES LEVEL PRESSURE SWITCH KIT 375431 TENNANT Ref. Part No. Description Qty. 375428 Switch assy, press 3 inch, 34” tube TENNANT COMPANY P. O. Box 1452 Minneapolis, MN 55440-1452 IB 340487 (6-01) LITHO IN U.S.A.

This manual is also suitable for:

73007100820082108300