Rs232 (X6-Ser1); Pin Assignment; Termination; Fig. 7-11: 25 Pin D-Sub Female Connector Strip - Bosch Rexroth IndraControl VCP 05.2 Project Planning Manual

Table of Contents

Advertisement

R911310377 / 02 | Rexroth IndraControl VCP 05
Interfaces
7.2.2

RS232 (X6-SER1)

7.2.2.1 Pin Assignment

7.2.2.2 Termination

Electric Drives and Controls | Bosch Rexroth AG
The interface is suitable to establish a point-to-point connection.

Fig. 7-11: 25 pin D-SUB female connector strip

Connector in the small operator terminal: 25 pin D-SUB female con-
nector strip
Pin Designation Function
6
TD
Transmitted Data
15
CTS
Clear to Send
17
RTS
Request to Send
18
RD
Received Data
25
SGND
Signal Ground

Fig. 7-12: Pin assignment RS232

The D-SUB connector strips must be shielded sufficiently. See chapter
"Shielding D-SUB Connectors" on page 7-15.
When channel SER1 is operated as a RS232, switch OFF the termina-
tion for the RS485.
7-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents