Download Print this page

EOS 38 AS Installation And Operating Manual

Electric sauna heater

Advertisement

Available languages

Available languages

All manuals and user guides at all-guides.com
M
-
G
E
-S
ONTAGE
UND
EBRAUCHSANWEISUNG FÜR
LEKTRO
AUNAOFEN
I
O
G
E
S
H
NSTALLATION AND
PERATING
UIDE FOR
LECTRIC
AUNA
EATER
I
'
NSTRUCTIONS DE MONTAGE ET D
UTILISATION DE FOURS DE SAUNA ÉLECTRIQUES
38 AS
MADE IN GERMANY
IP x4
Druck Nr. 29342172 / - 44.04
20012552

Advertisement

loading
Need help?

Need help?

Do you have a question about the 38 AS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EOS 38 AS

  • Page 1 All manuals and user guides at all-guides.com ONTAGE EBRAUCHSANWEISUNG FÜR LEKTRO AUNAOFEN NSTALLATION AND PERATING UIDE FOR LECTRIC AUNA EATER NSTRUCTIONS DE MONTAGE ET D UTILISATION DE FOURS DE SAUNA ÉLECTRIQUES 38 AS MADE IN GERMANY IP x4 Druck Nr. 29342172 / - 44.04 20012552...
  • Page 2 All manuals and user guides at all-guides.com ° ° ° ° ° ° N L1 L2 L3 Betriebs- Saunaleuchte Absicherung Thermostat zeituhr Temperatur- begrenzer Netzschalter Rohrheizkörper Verteilerkasten bei 7,5 kW Silikonan- schlußleitung bauseitige Installation Saunaofen Abb. 1...
  • Page 3 All manuals and user guides at all-guides.com ° ° Anschlußleistung Mindestmaße der Be- und Entlüftung in cm in kW 35 x 3 35 x 4 35 x 5 35 x 6 Tabelle 1 Mindest-Querschnitte in mm² (Kupferleitung) Anschluß an 380-400 V AC 3N Anschluß- geeignet für Netzzuleitung...
  • Page 4 All manuals and user guides at all-guides.com Kabinenwand 400 V AC 3N 400 V AC 3N Ofenschutzgitter 8 cm 42 cm 8 cm Abb. 2 U V W N U V W N 400 V AC 3N 400 V AC 3N Wandaufhängung U V W N U V W N...
  • Page 5 All manuals and user guides at all-guides.com 20 cm Abb. 5 Abb. 7 Abb.6...
  • Page 6 All manuals and user guides at all-guides.com WARNUNG! Bedeckung und nicht gefüllter Steinkorb verursacht Brandgefahr ° ° BITTE DRINGEND BEACHTEN!
  • Page 7 All manuals and user guides at all-guides.com Die Forderung nach Fehlerstrom-Schutzeinrichtungen für Betriebsmittel der Schutzklasse I als Alternative zur Schutzkleinspannung ist entfallen. Der Ableitstrom darf bei Betriebstemperatur folgen- de Werte nicht überschreiten: - bei ortsfesten Wärmegeräten der Schutzklasse I 0,75 mA; oder 0,75 mA je kW Bemessungs- aufnahme des Gerätes, je nachdem, welcher Wert größer ist, mit einem Höchstwert von 5 mA.
  • Page 8 All manuals and user guides at all-guides.com Achtung!
  • Page 9 All manuals and user guides at all-guides.com ° ° ° ° ° ° N L1 L2 L3 4-hr. operating Sauna lamp Fuses Thermostat timer Temperature limiter Main power switch Coil radiator for Distributor box 7,5 kW Silicone power cable Local site installation Sauna heater Fig.
  • Page 10 All manuals and user guides at all-guides.com ° ° Minimum dimensions of Power input in kW fresh-air inlets and exhaust outlets in cm 35 x 3 35 x 4 35 x 5 35 x 6 Table 1 Minimum diameters in mm (copper lead) for connection to 380-400 V AC 3N Power input in Suitable for cabin size...
  • Page 11 All manuals and user guides at all-guides.com Cabin wall 400 V AC 3N 400 V AC 3N Heater safety grate 8 cm 42 cm 8 cm Fig. 2 U V W N U V W N 400 V AC 3N 400 V AC 3N Wall mounting bracket U V W N...
  • Page 12 All manuals and user guides at all-guides.com 20 cm Fig. 5 Fiig. 7 Fig.6...
  • Page 13 All manuals and user guides at all-guides.com WARNING! A covered or empty stone grate poses a fire hazard. ° ° URGENT WARNING!
  • Page 14 All manuals and user guides at all-guides.com The demand for protection against leakage current for equipment of protection class I alternatively to protective low voltage has been dropped. The leakage current may not exceed the following values during operation: - for stationary heaters of protection class I 0,75 mA; or 0,75 mA each kW input of the appliance, depending on the higher value, at a maximum value of 5 mA.
  • Page 15 All manuals and user guides at all-guides.com Attention!
  • Page 16 All manuals and user guides at all-guides.com ° ° ° ° ° ° N L1 L2 L3 Minuterie Protection Lampe de sauna par fusibles Thermostat Limiteur de température Interrupteur de réseau Radiateur Boîte de tubulaire distribution pour 7,5 kW Câble de raccordement en silicone Four de sauna...
  • Page 17 All manuals and user guides at all-guides.com ° ° ° ° ° Puissance de Cotes minimum de raccordement en kW l'aération et de la ventilation en cm 35 x 3 35 x 4 35 x 5 Tableau 35 x 6 n°...
  • Page 18 All manuals and user guides at all-guides.com Cloison de cabine 400 V AC 3N 400 V AC 3N Grille de protection du four 8 cm 42 cm 8 cm Illustr. 2 U V W N U V W N 400 V AC 3N 400 V AC 3N Suspension murale U V W N...
  • Page 19 All manuals and user guides at all-guides.com 20 cm Illustr. 5 Illustr. 7 Illustr.6...
  • Page 20 All manuals and user guides at all-guides.com AVERTISSEMENT! Un recouvrement et une corbeille à pierres non remplie provoquent un risque d'incendie. ° ° A OBSERVER IMPERATIVEMENT!
  • Page 21 All manuals and user guides at all-guides.com On a laissé tomber la demande de déclencheurs par courant de défaut pour outillage industriel de la classe de protection 1 alternativement à la tension faible de protection. Le courant de fuite à la température de service ne doit pas dépasser les valeurs suivantes: - pour les appareils de chauffage stationaires de la Dévisez la vis de sécurité...
  • Page 22 All manuals and user guides at all-guides.com Attention!