Troubleshooting - Graco E-Flo DC 333389E Instructions - Parts Manual

2-ball piston pumps
Table of Contents

Advertisement

Troubleshooting

Troubleshooting
Troubleshooting
Troubleshooting
• Follow the
Pressure Relief Procedure, page
14
before checking or servicing the equipment.
• Check all possible problems and causes before
disassembly.
Problem
Problem
Problem
Pump output low on both strokes.
Pump output low on only one stroke.
No output.
Pump operates erratically.
Pump will not operate.
16
Cause
Cause
Cause
Inadequate power.
Exhausted fluid supply.
Clogged fluid outlet line, valves, etc.
Worn piston packing.
Held open or worn ball check valves. Check and repair. See lower manual.
Worn piston packing.
Improperly installed ball check
valves.
Exhausted fluid supply.
Held open or worn ball check valves. Check and repair. See lower manual.
Worn piston packing.
Inadequate power.
Exhausted fluid supply.
Clogged fluid outlet line, valves, etc.
Fluid dried on piston rod.
• The LED on the motor blinks if an error is detected.
See Error
Error Code
Error
Code Troubleshooting
Code
Troubleshooting in the motor
Troubleshooting
manual for more information.
Solution
Solution
Solution
See
Power Requirements, page 8
Refill and reprime pump.
Clear.
Replace. See lower manual.
Replace. See lower manual.
Check and repair. See lower manual.
Refill and reprime pump.
Replace. See lower manual.
See
Power Requirements, page 8
Refill and reprime pump.
Clear.
Disassemble and clean pump. See
lower manual. In future, stop pump
at bottom of stroke.
.
.
333389E

Advertisement

Table of Contents
loading