Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.

Location

Location
Location
When selecting the location for the equipment, keep
the following in mind:
• There must be sufficient space on all sides of
the equipment for installation, operator access,
maintenance, and air circulation.
• Ensure that the mounting surface and mounting
hardware are strong enough to support the weight
of the equipment, fluid, hoses, and stress caused
during operation.
• There must be a start/stop control (C)
within easy reach of the equipment. See
Typical Installation, page
Mount the
the Pump
Pump
Mount
Mount
the
Pump
Stand Mount
Stand
Stand
Mount
Mount
See
Stand Mounting Hole Pattern, page 30
1. Select a level surface for the stand to be mounted
to.
2. Secure the stand to the floor with M19 (5/8 in.)
bolts. Use bolts that engage at least 152 mm
(6 in.) into the floor to prevent the pump from
tipping.
3. Place the pump and accessories over the
bracket's mounting holes and secure with bolts
(5) and washers (4) supplied.
4. Use shims to level the pump as required.
8
10.
Wall Mount
Mount
Wall
Wall
Mount
See
Wall Mounting Hole Pattern, page
1. Select a solid position on a wall for the mounting
bracket. The wall should be capable of supporting
the pump and accessories that will be attached
to the bracket, any additional weight of the fluid
used in the pump, and any stress or strain that
may be applied during pump operation.
2. Drill four 7/16 in. (11 mm) diameter holes for the
mounting bolts, approximately 5 ft (1.5 m) above
the floor, using the wall bracket as a template.
Use any of the three mounting hole groupings
3. Bolt the bracket securely to the wall. Use bolts
designed to hold in the wall's construction.
4. Place the pump and accessories over the
bracket's mounting holes and secure with screws
(5) and washers (4) supplied.

Power Requirements

Requirements
Power
Power
Requirements
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
• This equipment must be grounded. Connect
only to a grounded power source.
• All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
The system requires a dedicated circuit protected
with a circuit breaker. See the following table for
power requirements.
Table 1 1 1 . . . Power
Power Specifications
Specifications
Table
Table
Power
Specifications
Model
Voltage
Model
Model
Voltage
Voltage
ESx3xx
200–250
ESx4xx
Vac
ESx7xx
ESx8xx
380–480
ESxCxx
ESxDxx
Vac
ESxGxx
ESxHxx
31.
Phase
Hz
Power
Phase
Phase
Hz
Hz
Power
Power
1
50/60
2.9 kVA
3
50/60
3.0 kVA