Wiring for TMCC or LEGACY

T
o power your accessory in the Command Control and LEGACY environments, you will
need an SC-2 (6-22980), an ASC (6-14182), or an ASC2 (6-81639). You will also need an
8" 3-pin female pigtail (available separately, 6-82038) and a transformer (6-14198).
Note
Refer to your CAB-1, CAB-1L, or LEGACY manual for remote instructions.

SC-2 wiring and operation

T
hree wires are needed to connect your accessory to the SC-2 and a separate accessory trans-
former.
1. Attach a wire to the transformer Common/Ground/U terminal and connect it to the COMM
(common) position on the SC-2.
2. Connect the black wire of the pigtail to the AUX2 terminal on the SC-2.
3. Connect the red wire of the pigtail to the transformer Power/A terminal.
4. Press Aux2 to turn the accessory on. Pressing Aux2 again will turn it off.
SC-2
Transformer
Figure 6. Wiring an SC-2.
3-pin male
connector
ACC1
ACC2
ACC3
ACC4
Red wire
9
3-pin female
connector
Black wire
8" 3-pin female
pigtail (6-82038)