Configure Gpio Signal Levels - Dalsa GiGE Vision Spyder3 Series User Manual

Hide thumbs Also See for GiGE Vision Spyder3 Series:
Table of Contents

Advertisement

Spyder3 GigE Vision SG-14 Cameras User's Manual
Pin
Signal
2
IN PUT_0-
3
IN PUT_1+
4
IN PUT_1-
5
GN D
6
IN PUT_2+
7
IN PUT_2-
8
IN PUT_3
9
OUTPUT_3
10
OUTPUT_2+
11
OUTPUT_0+
12
OUTPUT_0-
13
OUTPUT_1+
14
OUTPUT_1-
15
OUTPUT_2-

Configure GPIO Signal Levels

Before using any external triggers, the input lines mu st be set to a proper signal level: either TTL
(transistor-transistor logic) or LVDS (low -voltage d ifferential signaling). The Spyd er 3 GigE cameras
hard w ire 3 input lines that require signal level selection :
Line0 – line trigger or rotary encod er phase A inp ut
Line1 - Frame trigger
Line2 – Direction control or rotary encod er phase B input
Steps 1
Select the line: 0, 1, 2.
Steps 2
Select the correspond ing signal form at: TTL or LVDS.
Teledyne DALSA
All manuals and user guides at all-guides.com
LVDS (negative)
LVDS/ TTL format (p ositive)
LVDS (negative)
LVDS/ TTL format (p ositive)
LVDS (negative)
TTL auxiliary input
TTL auxiliary outpu t
LVDS/ TTL auxiliary outpu t
LVDS/ TTL auxiliary outpu t
LVDS (negative)
LVDS/ TTL auxiliary outpu t
LVDS (negative)
LVDS (negative)
Table 15: GPIO Signals
Figure 32: Inputs
Description
65
03-032-20123-00