Input/Output Tab; Schedule Tab - Generac Power Systems Magnum Series Operating Manual

Diesel generator with powerzone controller
Table of Contents

Advertisement

General Information
To scroll down within the event log, press the Enter () button. The scroll bar will change to blue, signifying it is
active. Press the ▲ or  buttons to scroll up or down in the event log. When finished, press the Enter () button again.

Input/Output Tab

The Input/Output (I/O) tab shows a list of digital inputs and outputs connected to the controller, whether they are
active and the current state (open/closed status) of the input and output.

Schedule Tab

The Scheduler tab shows the current configuration and status of the scheduler, located below the generator summary.
At the bottom of the screen, the maintenance configuration status and time remaining until an alarm, electrical trip
or shutdown will occur. The lamp(s) to the left shows the configuration status of the maintenance alarm, not the alarm
condition.
20
SITE
Return Delay
kW
kVAr
Digital Inputs
Ip Description
Active
GEN
A
B
C
+ -
V
D
E
F
1/38
Engine
Generator
Figure 2-16. Input/Output Tab Screen
SITE
Return Delay
kW
kVAr
Scheduler Enabled to run Reserved Reserved
Event
Week
Day
Start
Stop
GEN
1
All
Monday
00:00
00:00
2
All
Monday
00:00
00:00
3
All
Monday
00:00
00:00
4
All
Monday
00:00
00:00
+ -
5
All
Monday
00:00
00:00
V
6
All
Monday
00:00
00:00
7
All
Monday
00:00
00:00
8
All
Monday
00:00
00:00
Maintenance
Alarm
Hours
Date
Time
1
250:00
250 hr Maint. - Refer to Manual
2
500:00
500 hr Maint. - Refer to Manual
3
3000:00
3000 hr Maint. - Refer to Manual
Engine
Generator
1/1
Figure 2-17. Schedule Tab Screen
MMG130DI4/175DI4/205DI4 Operating Manual
GENSET
7741 \ 7740
480V/277V 3-Phase
10:00:00
Total
Generator
0.0
0.0
kW
0.0
0.0
Hz
kVA
0.0
kVAr
0.0
0.0
%
0.00
0.0
pf
0.0
%
State
Ip Description
Active
G
H
I
J
K
Alarms
Schedule
Status
I/O
00406
GENSET
7741 \ 7740
480V/277V 3-Phase
10:00:00
Total
Generator
0.0
kW
0.0
0.0
0.0
kVA
Hz
0.0
0.0
kVAr
0.0
%
0.00
0.0
0.0
pf
%
Duration
Event
Week
Day
Start
Stop Duration
0:00
9
All
Monday
00:00
00:00
0:00
10
All
Monday
00:00
00:00
0:00
11
All
Monday
00:00
00:00
0:00
12
All
Monday
00:00
00:00
0:00
13
All
Monday
00:00
00:00
0:00
14
All
Monday
00:00
00:00
0:00
15
All
Monday
00:00
00:00
0:00
16
All
Monday
00:00
00:00
Description
Action
Warning
Warning
Warning
Alarms
Schedule
Status
I/O
00407
07:10
kWh+
kVAh
kVArh
State
07:10
kWh+
kVAh
kVArh
0:00
0:00
0:00
0:00
0:00
0:00
0:00
0:00
33722 D