Climatic environmental conditions
Installation altitude
Relative humidity
Oil mist, salt mist, ice formation, con‐
densation, dripping water, spraying
water, splashing water and water jets
Biological, chemical and mechanical influences, pollutants
Biological environmental conditions
Chemically active environmental con‐
ditions
Mechanically active environmental
conditions
Classification of the mechanical
environment
Vibration test in operation
Shock test in operation
Degree of contamination
EMC conducted / radiation
Note
The user must consider radio interference for the complete system. Particular attention should
be paid to cabling. Please contact your sales representative for assistance and support.
If compliance with limit value class C2 is required, please contact your local sales
representative.
TCU 30.3
Manual, 09/2017, A5E40874197
7.3 Climatic and mechanical environmental conditions
Up to 1000 m without derating
From 1000 m to 4000 m with linear ambient temperature de‐
rating, -0.5 K per 100 m
5 ... 95% (no condensation)
Not permitted
Class 3B1 according to EN 60 721-3-3:
Mold, mold growth, slime, rodents, termites and other animal
vermin are not permissible.
Class 3C1 according to EN 60721‑3‑3
Class 3M1 according to EN 60721‑3‑3:
Conductive dust not permissible.
3M3 for components on the machine
3M1/3M2 for components in the control cabinet
According to IEC 60068-2-6 test Fc (sinusoidal)
● 10...57 Hz: 0.075 mm deflection amplitude
● 57...150 Hz: 1 g acceleration amplitude
● 10 frequency cycles per axis
According to IEC 60068-2-27 test Ea (half-sine)
● 5 g peak acceleration
● 30 ms duration
● 3 shocks in all three axes in both directions
2 (only use indoors)
Class C3 according to EN 61800-3
Technical data