Specifications
8.3 Output
Definition
Min.
Output voltage
0
U
o normal
Tolerance, static
0
(incl. line
regulation)
Load regulation
0
(0% / 100%
nominal current)
Ripple
–
Rated power
–
P
o nominal
Rated current
–
I
o nominal
Current limitation
10.1
"10 A"
Current limitation
7.5
"reduced"
Current limitation
3.5
at "thermal
warning level"
Short circuit
Yes, continuously
rigidity
Efficiency
92
No load input
–
power
Parallel operation
Up to 3 units
Potential
Output is floating
conditions
Ext. allowed
0
capacity at U
o
Over-voltage
305
protection
(normal) OVP
Table 8.3 Output Data
®
VLT
ISD Power Supply Module Operating Instructions
Type
Max.
300 (default)
300
0
+/-1
-1.5 (default)
-7.5
–
1
3000
–
10
–
10.2
10.5
7.8
7.9
–
4.5
93
–
15
–
–
>15
–
335
®
MG75H102 - VLT
is a registered Danfoss trademark
Unit
Condition
V
–
DC
%
–
%
–
V
BW = 20 MHz
pp
W
–
A
Control input "10
A" active
A
Control input "10
A" active
A
–
A
–
–
%
–
W
–
–
Test voltage > DC
1000 V output
against PE
mF
Output stable
V
Average value
DC
Remark
Reduction
possible via
CANopen
interface
–
Adjustable in 16
steps via
CANopen
interface
–
–
–
8
–
Control input "10
A" open
If fan blocked or
heat sink
temperature too
high
–
–
–
Load sharing
supported by
"downslope"
characteristic
Normally 1 pole of
the output will be
grounded in the
application
–
Non-latching
19