3-3. Connection Cable Installation

• Connect the connection cable to the left or right of the scale head, selecting left or right depending on
the installation location.
• A waterproof cap is fi tted to both ends of the scale head. Remove the waterproof cap from the end where
the cable is to be connected and connect the cable. (Water-proof cap hexagon socket opposite side 5 mm)
• Use a tightening torque of 1.0 N·m for the connector that is used for the connection with the scale head.
• Apply a thread-locking agent to the threaded area of the connector used for connection in order to
prevent looseness. (Loctite 242)
Notes
Do not remove the waterproof cap from the end that is not connected. If the cap comes off , re-install it
securely. Using the scale unit without the cap may result in damage to the scale head.
Thread-locking agent
Tightening torque:
1.0 N·m
Water-proof cap
SR27A-AZ Series, CH22 Series
2
3
1
11
(E)